高频超声在评估静脉溃疡患者皮肤水肿中的应用。

Utility of high-frequency ultrasound in assessing cutaneous edema in venous ulcer patients.

机构信息

Department of Dermatology and STD, JIPMER, Puducherry, India.

出版信息

Skin Res Technol. 2021 Sep;27(5):904-908. doi: 10.1111/srt.13040. Epub 2021 Mar 25.

Abstract

BACKGROUND

High-frequency ultrasound (HFUS) using a 20 MHz probe is a non-invasive assessment tool. Its utility in dermatology for diagnosis of disease or for monitoring of treatment response in various dermatological conditions is still being explored. Edema secondary to venous hypertension is the main pathogenic factor in the development of venous leg ulcers. However, there is no objective method for assessment of degree of edema. In this study, we explore the utility of high-frequency ultrasound in assessing cutaneous edema and for monitoring its improvement with compression therapy among patients with venous ulcer.

MATERIALS AND METHODS

Twenty patients with venous ulcer were enrolled in the study. Measurement of cutaneous edema was done at baseline and after 2 weeks of compression therapy in all patients. The 3 levels of measurement were dorsum of foot (low site, L1), 4 cm proximal to the medial malleolus (middle site, L2), and the medial aspect of the calf between the medial malleolus and the knee (upper site, L3).

RESULTS

Baseline subepidermal low echogenic band (SLEB) measurements were 2.46 ± 0.69 mm, 2.94 ± 0.65 mm, and 2.66 ± 0.64 mm at L1, L2, and L3, respectively. There was a significant reduction in SLEB measurement after compression therapy ( p values 0.008, 0.002, and 0.003 at L1, L2, and L3, respectively). The mean percentage reduction in SLEB at level of medial malleolus (mid level - 29.61 ± 12.24) was higher than the other 2 sites (L1-22.45 ± 15.83 and L3 were 27.57 ± 12.34).

CONCLUSION

Cutaneous ultrasound aids in accurate assessment of level and severity of edema. Hence, it can be utilized in trials to objectively assess the adequacy of treatment for patients with venous insufficiency.

摘要

背景

使用 20MHz 探头的高频超声(HFUS)是一种非侵入性评估工具。它在皮肤科中的应用,无论是用于诊断疾病,还是用于监测各种皮肤科疾病的治疗反应,仍在探索之中。静脉高压引起的水肿是静脉性腿部溃疡发展的主要致病因素。然而,目前还没有评估水肿程度的客观方法。在这项研究中,我们探索了高频超声在评估皮肤水肿中的效用,并在静脉溃疡患者中监测其在压缩治疗后的改善情况。

材料与方法

20 例静脉性溃疡患者纳入本研究。所有患者在基线时和接受 2 周压缩治疗后均进行皮肤水肿测量。测量的 3 个部位为足背(低位,L1)、内踝近端 4cm(中位,L2)和内踝与膝盖之间的小腿内侧(高位,L3)。

结果

基线时皮下低回声带(SLEB)的测量值分别为 L1、L2 和 L3 处的 2.46±0.69mm、2.94±0.65mm 和 2.66±0.64mm。接受压缩治疗后,SLEB 测量值显著降低(L1、L2 和 L3 处的 p 值分别为 0.008、0.002 和 0.003)。内踝水平的 SLEB 平均降低百分比(中水平-29.61±12.24)高于其他 2 个部位(L1-22.45±15.83 和 L3-27.57±12.34)。

结论

皮肤超声有助于准确评估水肿的程度和严重程度。因此,它可以在临床试验中用于客观评估静脉功能不全患者治疗的充分性。