Suppr超能文献

处理技术对骨-前交叉韧带-骨同种异体移植物力学性能的影响。山羊的实验研究。

The effects of processing techniques on the mechanical properties of bone-anterior cruciate ligament-bone allografts. An experimental study in goats.

作者信息

Jackson D W, Grood E S, Wilcox P, Butler D L, Simon T M, Holden J P

机构信息

Southern California Center for Sports Medicine, Long Beach 90806.

出版信息

Am J Sports Med. 1988 Mar-Apr;16(2):101-5. doi: 10.1177/036354658801600203.

Abstract

There has been a growing interest in the use of allografts as ACL substitutes. Allografts are often freeze dried to increase shelf storage time and sterilized with ethylene oxide. This study was conducted to determine the effect of a specific ethylene oxide sterilization procedure and freeze drying process on the initial mechanical properties of femur-ACL-tibia preparations. Twelve knees (stifle joints) from six mature goats were divided into two groups (one knee of pair to each group). Knees were cleaned of all soft tissue except for the anterior cruciate, posterior cruciate, and collateral ligaments. Group 1 was sterilized with ethylene oxide (simulating clean procurement) then freeze dried. Group 2 was freeze dried only (simulating sterile procurement). The knees were rehydrated and then tested in tension to failure to determine their structural mechanical properties. The ethylene oxide-freeze dried specimens (Group 1) had a mean maximum load before failure of 2059 +/- 273 newtons (N) (+/- SE) which was not statistically different than the maximum load of the freeze dried specimens (Group 2) of 2023 +/- 214 N. The average strength of Group 1 and 2 combined was not significantly different than a third group of 12 normal femur-ACL-tibia controls which had an average maximum force of 2403 +/- 133 N. No significant differences between the groups were observed for stiffness, energy to maximum strength, or elongation to maximum force. It appears the freeze dry processing, with or without ethylene oxide sterilization, using the procedure we used, has, at most, a small effect on the initial mechanical properties of the preparations.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

同种异体移植物作为前交叉韧带替代物的应用已引起越来越多的关注。同种异体移植物通常经过冻干处理以延长货架储存时间,并用环氧乙烷进行灭菌。本研究旨在确定特定的环氧乙烷灭菌程序和冻干过程对股骨-前交叉韧带-胫骨标本初始力学性能的影响。从六只成年山羊身上获取的12个膝关节( stifle关节)被分为两组(每组一对膝关节中的一个)。除前交叉韧带、后交叉韧带和侧副韧带外,所有膝关节的软组织均被清理干净。第1组先用环氧乙烷灭菌(模拟清洁获取),然后进行冻干。第2组仅进行冻干(模拟无菌获取)。膝关节复水后进行拉伸直至破坏试验,以确定其结构力学性能。环氧乙烷冻干标本(第1组)破坏前的平均最大负荷为2059±273牛顿(N)(±标准误),与冻干标本(第2组)的最大负荷2023±214 N相比,无统计学差异。第1组和第2组合并后的平均强度与第三组12个正常股骨-前交叉韧带-胫骨对照标本的平均最大力2403±133 N相比,无显著差异。各组之间在刚度、达到最大强度的能量或达到最大力时的伸长率方面均未观察到显著差异。看来,使用我们所采用的程序,无论是否进行环氧乙烷灭菌,冻干处理对标本的初始力学性能至多只有微小影响。(摘要截短至250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验