St. Christopher's Hospital for Children, Department of General, Thoracic, and Minimally Invasive Surgery, 160 East Erie Avenue, Philadelphia, PA 19123, USA.
Sidney Kimmel Medical College, Thomas Jefferson University 1025 Walnut St, Philadelphia, PA 19107, USA.
J Pediatr Surg. 2021 Jun;56(6):1180-1184. doi: 10.1016/j.jpedsurg.2021.02.037. Epub 2021 Feb 24.
Clinical practice guidelines recommend performing head CT and skull radiographs (SR) when evaluating infants for physical abuse. We compared the accuracy of 3-dimensional CT (3DCT) and SR for detecting skull fractures.
We reviewed children <12 months evaluated for physical abuse undergoing 3DCT and SR between January 2017 and December 2018. 3DCT and SR images were blindly read by 2 radiologists. Interrater reliability (IRR) was calculated. Diagnostic accuracy was compared using McNemar's test.
158 infants with a mean age of 5.0 months underwent 3DCT and SR. Consensus reading identified 46 fractures (29.1%) on 3DCT and 40 fractures (25.3%) on SR. IRR was higher for 3DCT (κ = 0.95) than for SR (=0.65). 11 fractures were identified on 3DCT but not SR. 5 fractures were identified on SR but not 3DCT. There was no difference in the diagnostic accuracy of 3DCT and SR (χ = 1.56, p = 0.211).
We found no difference in the accuracy of 3DCT and SR for detecting skull fractures in infants. Because 3DCT has better IRR and evaluates for both bony and intracranial injuries it is superior to SR. Omitting SRs may be acceptable if a 3DCT is performed, and would reduce radiation exposure without compromising diagnostic accuracy.
临床实践指南建议在评估婴儿身体虐待时进行头部 CT 和颅骨 X 线摄影(SR)。我们比较了 3 维 CT(3DCT)和 SR 检测颅骨骨折的准确性。
我们回顾了 2017 年 1 月至 2018 年 12 月期间接受 3DCT 和 SR 检查的 12 个月以下因身体虐待而接受评估的儿童。由 2 名放射科医生对 3DCT 和 SR 图像进行盲法阅读。计算了组内相关系数(IRR)。采用 McNemar 检验比较诊断准确性。
158 名平均年龄为 5.0 个月的婴儿接受了 3DCT 和 SR 检查。共识阅读在 3DCT 上发现 46 处骨折(29.1%),在 SR 上发现 40 处骨折(25.3%)。3DCT 的 IRR 高于 SR(κ=0.95 对 0.65)。3DCT 上发现 11 处 SR 上未发现的骨折。SR 上发现 5 处 3DCT 上未发现的骨折。3DCT 和 SR 的诊断准确性无差异(χ=1.56,p=0.211)。
我们发现 3DCT 和 SR 检测婴儿颅骨骨折的准确性没有差异。由于 3DCT 的 IRR 更高,并且可以评估骨和颅内损伤,因此优于 SR。如果进行 3DCT,则可以省略 SR,从而减少辐射暴露而不影响诊断准确性。