Faculty of Health Sciences, Universidad Rey Juan Carlos, 28922 Madrid, Spain.
Faculty of Nursing, Physical Therapy and Podiatry, Universidad Complutense de Madrid, 28040 Madrid, Spain.
Int J Environ Res Public Health. 2021 Mar 22;18(6):3265. doi: 10.3390/ijerph18063265.
The analysis of the center of pressure (COP) is a method used to assess the foot function, but its reliability and repeatability have not been evaluated. COP can be altered by diverse conditions, like an excessive foot pronation. Low-Dye taping is commonly used for the treatment of symptoms related to an excessive pronation. To date, no study has evaluated the effects of the Low-Dye taping on COP and the duration of its effects. Thus, the main purpose of this manuscript was to assess the reliability and repeatability of the percentage of center of pressure locus area (%CLA) in feet with an excessive pronation, and secondarily, to assess that the Low-Dye taping modifies the %CLA during the immediate 48 h.
An observational study of the reliability and repeatability of the %CLA variable with the Low-Dye taping in feet with excessive pronation was carried out. We used the EPS-Platform to evaluate the results of the variable in 6 conditions in a first session to evaluate the reliability of the results. We compared the results of the first session with the results in a second session to evaluate the repeatability of the results. We also carried out an ANOVA test to evaluate the changes that the taping produced in the variable between without taping with the rest of the 6 conditions.
For the %CLA, we observed a reliability greater than 0.80, measured by the interclass ratio index, both in the first session before taping, and in the second session before taping, thus being a repeatability variable. In the following times, with taping, at 10 min with tape, at 20 min with tape, at 24 h with tape and at 48 h with tape; an interclass ratio coefficient (ICC) higher than 0.80 was again obtained, thus being a reliable variable in all measurements made. The Low-Dye taping did not change %CLA from the time the tape was put in until 48 h (-value = 1.000).
The %CLA variable, in feet with excessive pronation, proved to be a reliable variable in all the measurements obtained before putting on the tape and during the following 48 h with the tape, and a repeatable variable. The Low-Dye taping did not change the %CLA from the time the tape was put in until 48 h.
足底压力中心(COP)分析是一种用于评估足部功能的方法,但尚未评估其可靠性和可重复性。 COP 可能会因各种情况而改变,例如过度的足部旋前。 低染料贴扎术常用于治疗与过度旋前相关的症状。 迄今为止,尚无研究评估低染料贴扎术对 COP 的影响及其影响持续时间。 因此,本文的主要目的是评估过度旋前足的 COP 轨迹面积百分比(%CLA)的可靠性和可重复性,其次是评估低染料贴扎术在 48 小时内是否会改变 %CLA。
对过度旋前足的低染料贴扎术的 %CLA 变量的可靠性和可重复性进行了观察性研究。 我们使用 EPS 平台在第一次会议的 6 种条件下评估变量的结果,以评估结果的可靠性。 我们将第一次会议的结果与第二次会议的结果进行比较,以评估结果的可重复性。 我们还进行了方差分析测试,以评估在不贴扎和其余 6 种条件下,贴扎术对变量的变化。
对于 %CLA,我们观察到在第一次会议之前(即不贴扎时)和第二次会议之前(即不贴扎时),内类比指数测量的可靠性均大于 0.80,因此是一个可重复性变量。 在接下来的时间里,在有贴扎的情况下,在贴扎后 10 分钟、20 分钟、24 小时和 48 小时,再次获得了内类比系数(ICC)大于 0.80 的结果,因此在所有测量中都是可靠的变量。 低染料贴扎术从贴扎开始到 48 小时内并未改变 %CLA(-值=1.000)。
在过度旋前的足部中,%CLA 变量在贴扎前和接下来的 48 小时内的所有测量中均为可靠变量,并且为可重复变量。 低染料贴扎术从贴扎开始到 48 小时内并未改变 %CLA。