高中棒球投手肩部旋转力量的等速评估

Isokinetic evaluation of shoulder rotational strength in high school baseball pitchers.

作者信息

Hinton R Y

机构信息

Sports Medicine Clinic, Children's Hospital, Baltimore, Maryland.

出版信息

Am J Sports Med. 1988 May-Jun;16(3):274-9. doi: 10.1177/036354658801600314.

Abstract

Isokinetic, shoulder rotational strength was evaluated in 26 high school baseball pitchers before the start of spring practice. Using the Cybex II (Cybex, Division of Lumex, Inc., Ronkonkoma, NY), test data were gathered on the dominant and nondominant shoulders in the supine 90 degrees abducted test position (90 degrees AbTP) and the standing neutral test position (neutral TP). Tests were performed at 90 and 240 deg/sec. The HUMAC (Computer Sports Medicine, Inc., Flemington, NJ) computer system was used to analyze data. Means and standard deviations for peak torque, total work, peak torque to body weight ratios, and agonist/antagonist ratios are presented. Comparison of dominant to non-dominant sides and 90 degrees AbTP to neutral TP values are reported. Peak torque and total work values for the throwing side internal rotators were significantly higher than the nonthrowing side in all tests. Pitching side external rotators failed to show this dominance. External/internal rotation ratios for peak torque and total work were significantly lower on the pitching side, suggesting a relative imbalance of cuff musculature compared to the nonpitching shoulder. Significant differences existed between data gathered in the two different test positions. In the 90 degrees AbTP, external rotation peak torque and total work values and external/internal rotation peak torque and total work ratios were higher than the equivalent values gathered in the neutral TP. Internal rotation peak torque and total work values tended to be higher in the neutral TP than in the 90 degrees AbTP.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

在春季训练开始前,对26名高中棒球投手的等速肩部旋转力量进行了评估。使用Cybex II(Cybex,Lumex公司分部,纽约州罗恩科马),在仰卧位90度外展测试位置(90度AbTP)和站立中立测试位置(中立TP)收集优势肩和非优势肩的测试数据。测试在90和240度/秒的速度下进行。使用HUMAC(新泽西州弗莱明顿计算机运动医学公司)计算机系统分析数据。给出了峰值扭矩、总功、峰值扭矩与体重比以及 agonist/antagonist 比的均值和标准差。报告了优势侧与非优势侧以及90度AbTP与中立TP值的比较。在所有测试中,投掷侧内旋肌的峰值扭矩和总功值显著高于非投掷侧。投球侧外旋肌未显示出这种优势。投球侧峰值扭矩和总功的外旋/内旋比显著较低,表明与非投球肩相比,袖带肌肉组织存在相对失衡。在两个不同测试位置收集的数据之间存在显著差异。在90度AbTP中,外旋峰值扭矩和总功值以及外旋/内旋峰值扭矩和总功比高于在中立TP中收集的等效值。中立TP中的内旋峰值扭矩和总功值往往高于90度AbTP中的值。(摘要截断于250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验