is a full-time CRNA with Infinity Healthcare at a variety of Ascension Hospitals throughout metropolitan Milwaukee, Wisconsin. Her research focuses on endotracheal tube cuff pressures and inflation methods.
is a full-time CRNA at NorthShore University HealthSystem in Evanston, Illinois. Her research focuses on endotracheal tube cuff pressures.
AANA J. 2021 Apr;89(2):147-154.
Adverse effects associated with elevated endotracheal (ET) tube cuff pressures above 25 cm H2O include postoperative throat pain and tissue ischemia. Anesthesia practitioners' current methods of cuff pressure estimation are often inaccurate. This quantitative, quasi-experimental quality improvement project evaluated the incidence of ET tube cuff overinflation before and after an educational intervention that recommended the use of a 5-mL over 10-mL syringe for cuff inflation. Cuff pressures were measured at 2 hospitals within a large academic health system. The mean ET tube cuff pressure before education was 46.8 cm H2O and after education was 27.1 cm H2O (P=.001). The postintervention average cuff pressure using a 10-mL syringe was 36.8 cm H2O vs 21.1 cm H2O when providers used a 5-mL syringe (P=.039). The relationship between syringe size and cuff pressure was significant (P=.001) with a positive Pearson correlation of 0.471. The ET tube cuff pressures were reduced by 42% after the intervention. Average cuff pressures when providers used a 5-mL syringe were 55% lower than with use of a 10-mL syringe. No critically high postintervention pressures were recorded when a 5-mL syringe was used. The authors recommend 5-mL syringes be used for inflation of an ET tube cuff.
当气管内(ET)管套囊压力高于 25cmH2O 时,会出现与升高相关的不良影响,包括术后喉咙疼痛和组织缺血。麻醉师目前估计套囊压力的方法往往不准确。这项定量、准实验性的质量改进项目评估了在教育干预前后,ET 管套囊过度充气的发生率,该教育干预建议使用 5 毫升注射器而非 10 毫升注射器来充气套囊。在一个大型学术医疗系统内的 2 家医院测量了套囊压力。在教育之前,ET 管套囊压力的平均值为 46.8cmH2O,在教育之后为 27.1cmH2O(P=.001)。当使用 10 毫升注射器时,干预后套囊平均压力为 36.8cmH2O,而当使用 5 毫升注射器时为 21.1cmH2O(P=.039)。注射器大小与套囊压力之间存在显著关系(P=.001),皮尔逊相关系数为 0.471。干预后,ET 管套囊压力降低了 42%。当使用 5 毫升注射器时,套囊压力的平均水平比使用 10 毫升注射器低 55%。当使用 5 毫升注射器时,没有记录到干预后压力非常高的情况。作者建议使用 5 毫升注射器来充气 ET 管套囊。