AIMS

The study compared changes in implant stability and bone loss of implants with different designs using early loading at 6 weeks.

SETTING AND DESIGN

In vivo-comparative study.

MATERIALS AND METHODS

Forty subjects were selected and divided randomly by sealed envelope method in Group X and Group A for early loading for missing single posterior tooth in mandible. Implants in Group X had flared crest module and buttress thread design, whereas implants in Group A had parallel crest module and V-shaped thread design. All subjects were evaluated by Ostell for implant stability at the interval of baseline, 6 weeks, 3 months, and 6 months. ImageJ software was used for measurement of crestal bone loss in intraoral periapical radiographs at the interval of 6 weeks, 3 months, and 6 months.

STATISTICAL ANALYSIS USED

Unpaired t test, repeated ANOVA, Tukey post hoc test.

RESULTS

The mean bone loss values of Group X at predetermined interval were 1.51 ± 0.20 mm, 2.11 ± 0.21 mm and 2.13 ± 0.21 mm. The mean bone loss values of Group A were 1.79 ± 0.16 mm, 2.92 ± 0.23 mm and 2.95 ± 0.23 mm. The mean bone loss was statistical significant (P < 0.05) at 6 weeks, 3 months and 6 months. It was highly significant in Group A at 6 months (P < 0.001).

CONCLUSIONS

It was concluded that Group X implants design showed better implant stability and less bone loss when compared to Group A implants design.

摘要

目的

本研究比较了 6 周时早期负载对不同设计种植体稳定性和骨丢失的变化。

设置和设计

体内比较研究。

材料和方法

选择 40 名受试者,采用密封信封法随机分为 X 组和 A 组,用于下颌缺失单颗后牙的早期负载。X 组种植体具有喇叭形嵴模块和支撑螺纹设计,而 A 组种植体具有平行嵴模块和 V 形螺纹设计。所有受试者均采用 Ostell 进行基线、6 周、3 个月和 6 个月时的种植体稳定性评估。使用 ImageJ 软件在 6 周、3 个月和 6 个月时的口腔根尖片上测量牙槽嵴骨丢失量。

统计分析方法

配对 t 检验、重复方差分析、Tukey 事后检验。

结果

X 组在预定间隔的平均骨丢失值分别为 1.51 ± 0.20mm、2.11 ± 0.21mm 和 2.13 ± 0.21mm。A 组的平均骨丢失值分别为 1.79 ± 0.16mm、2.92 ± 0.23mm 和 2.95 ± 0.23mm。6 周、3 个月和 6 个月时,平均骨丢失值具有统计学意义(P<0.05)。A 组在 6 个月时具有高度统计学意义(P<0.001)。

结论

与 A 组种植体设计相比,X 组种植体设计显示出更好的种植体稳定性和更少的骨丢失。