Suppr超能文献

印度中部浦那一家三级护理医院中,X线片与计算机断层扫描测量气管直径的比较。

Comparison of Tracheal Diameter Measurements on Radiograph Versus Computed Tomography at a Tertiary Care Hospital in Pune, Central India.

作者信息

Ajmera Pranav, Prasad Niharika

机构信息

Radiology, Dr DY Patil Medical College, Hospital and Research Center, Pune, IND.

出版信息

Cureus. 2021 Mar 7;13(3):e13755. doi: 10.7759/cureus.13755.

Abstract

Background Variations in tracheal diameter with respect to factors like age and gender are one of the major factors affecting the size of the endotracheal tube (ETT) preferred in a patient. It is important to pre-determine this figure because a tube of a larger size predisposes the patient for tracheal mucosal ischemia, while one of a smaller size may not ensure adequate oxygen saturation in the patient. Purpose We undertook this study to assess the accuracy of radiograph versus computed tomography (CT) and comment on whether a CT should be carried out mandatorily in all patients where intubation is needed. Materials and methods The study was undertaken at Dr DY Patil Medical College, Hospital, and Research Center, a tertiary care institute in Pune, India. A total of 217 patients in whom both chest radiograph and chest CT were performed were enrolled in the study and measurements were performed at suitable landmarks which correspond to the position of endotracheal tubes. Results The males had a mean age of 44.2 years and females of 41.7 years. The mean X-ray transverse diameter was 15.4 ± 3.2 (SD) mm, mean CT axial transverse diameter was 15.3 ± 3.4 (SD) mm, mean CT sagittal diameter was 14.8 ± 3.7 (SD) mm, and the mean CT coronal diameter was 15.2 ± 3.5(SD)mm. Conclusions There was a significant difference in mean X-ray transverse diameter (Low kV), CT axial transverse diameter, CT sagittal diameter, and CT coronal diameter between males and females. Mean values were significantly higher in males as compared to females. There was a significant difference in tracheal diameters for different age groups, irrespective of the modality. Bland-Altman analysis revealed no significant difference between chest radiograph and CT for tracheal diameter measurement.

摘要

背景

气管直径随年龄和性别等因素的变化是影响患者首选气管内插管(ETT)尺寸的主要因素之一。预先确定这一数值很重要,因为尺寸较大的气管插管会使患者易发生气管黏膜缺血,而尺寸较小的气管插管可能无法确保患者有足够的氧饱和度。目的:我们开展这项研究以评估X线片与计算机断层扫描(CT)的准确性,并就所有需要插管的患者是否都应强制进行CT检查发表意见。材料与方法:该研究在印度浦那的一家三级医疗机构——DY帕蒂尔医学院、医院和研究中心进行。共有217例同时进行了胸部X线片和胸部CT检查的患者纳入研究,并在与气管内插管位置相对应的合适标志点进行测量。结果:男性的平均年龄为44.2岁,女性为41.7岁。X线片平均横向直径为15.4±3.2(标准差)mm,CT轴向平均横向直径为15.3±3.4(标准差)mm,CT矢状径平均为14.8±3.7(标准差)mm,CT冠状径平均为15.2±3.5(标准差)mm。结论:男性和女性在X线片平均横向直径(低千伏)、CT轴向横向直径、CT矢状径和CT冠状径方面存在显著差异。男性的平均值显著高于女性。不同年龄组的气管直径存在显著差异,与检查方式无关。Bland-Altman分析显示,胸部X线片和CT在气管直径测量方面无显著差异。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/88fc/8024437/fc4bdec242bd/cureus-0013-00000013755-i01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验