Suppr超能文献

乳制品废水处理厂的电能消耗结构和指标。

Structure and indicators of electric energy consumption in dairy wastewater treatment plant.

机构信息

Bielmlek Dairy Cooperative, Wojska Polskiego 52, 17-100 Bielsk Podlaski, Poland.

Faculty of Building Services Hydro and Environmental Engineering, Warsaw University of Technology, 20 Nowowiejska St., Warsaw 00-653, Poland.

出版信息

Sci Total Environ. 2021 Aug 15;782:146599. doi: 10.1016/j.scitotenv.2021.146599. Epub 2021 Mar 26.

Abstract

The aim of the research was to determine the indicators of electricity consumption in every stage of the dairy sewage treatment process in relation to the sewage flow and the load of removed organics (BOD, COD) and nutrients (TN, TP). The research was conducted in a dairy wastewater treatment plant (WWTP) consisting of mechanical treatment, averaging tank, dissolved air flotation (DAF) and biological treatment with sequence batch reactors (SBRs). Energy consumption was measured with the help of transducers. Indicators of unit electricity consumption were determined on the basis of 95 measurement series of energy consumption, sewage flow and removed load. The mean value of total unit energy consumption relating to the flow for the entire WWTP was 2.29 kWh·m, while for biological treatment 1.17 kWh·m and 0.05 kWh·m for DAF. The mean values of indicators relating to removed pollutants load for the entire WWTP were: 1.89 kWh·kg BOD, 1.30 kWh·kg COD, 48.61 kWh·kg TN and 160.01 kWh·kg TP. During biological treatment, energy consumption indicators were on average: 1.65 kWh·kg BOD and 1.19 kWh·kg COD, 52.90 kWh·kg TN and 141.26 kWh·kg TP, while for DAF: 0.12 kWh·kg BOD, 0.09 kWh·kg COD , 3.85 kWh·kg TN and 16.17 kWh·kg TP. It was found that the biological treatment in SBRs was responsible for 54.1% of the total energy consumption of dairy WWTP. Aerobic sewage sludge treatment accounted for 17.0% of total consumption, mechanical treatment 17.1%, deodorization 2.6%, and other (social, lighting etc.) 6.9%, while DAF only 2.3%. The real-time electricity metering system enabled the optimisation of the electricity consumption in the WWTP, taking into account its consumption in unit processes and the removed pollutants load. The application of this system enabled to make corrections that reduced energy consumption while maintaining the required treatment efficiency.

摘要

本研究旨在确定与污水流量以及去除有机物(BOD、COD)和营养物(TN、TP)负荷相关的各个阶段的乳制品污水处理过程的电力消耗指标。研究在一个由机械处理、平均池、溶气浮选(DAF)和序批式反应器(SBR)组成的乳制品废水处理厂(WWTP)中进行。使用传感器测量能源消耗。基于 95 个能源消耗、污水流量和去除负荷的测量系列,确定单位电力消耗指标。整个 WWTP 的总单位能耗与流量的平均值为 2.29 kWh·m,而生物处理为 1.17 kWh·m,DAF 为 0.05 kWh·m。整个 WWTP 的与去除污染物负荷相关的指标平均值为:1.89 kWh·kg BOD、1.30 kWh·kg COD、48.61 kWh·kg TN 和 160.01 kWh·kg TP。在生物处理过程中,能源消耗指标平均为:1.65 kWh·kg BOD 和 1.19 kWh·kg COD、52.90 kWh·kg TN 和 141.26 kWh·kg TP,而 DAF 为:0.12 kWh·kg BOD、0.09 kWh·kg COD、3.85 kWh·kg TN 和 16.17 kWh·kg TP。结果发现,SBR 中的生物处理负责乳制品 WWTP 总能耗的 54.1%。好氧污水污泥处理占总消耗的 17.0%,机械处理占 17.1%,除臭占 2.6%,其他(社会、照明等)占 6.9%,而 DAF 仅占 2.3%。实时电量计量系统使 WWTP 的电力消耗能够得到优化,考虑到其在各个单元过程中的消耗和去除的污染物负荷。该系统的应用使得可以进行校正,在保持所需处理效率的同时降低能源消耗。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验