Suppr超能文献

使用两种不同软件程序的 CEREC Omnicam 的时间和准确性。

Time and Accuracy of the CEREC Omnicam Using Two Different Software Programs.

机构信息

Prosthodontics Department, Naval Postgraduate Dental School, Naval Medical Leader & Professional Development Command, Postgraduate Dental College, Uniformed Services University of Health Sciences, Bethesda, MD.

Department of Research Programs, Walter Reed National Military Medical Center, Bethesda, MD.

出版信息

J Prosthodont. 2022 Feb;31(2):130-135. doi: 10.1111/jopr.13368. Epub 2021 Apr 30.

Abstract

PURPOSE

The purpose of this in vitro study was to evaluate the effect of software on scan time, trueness, and precision of digital scans created using the CEREC Omnicam.

MATERIAL AND METHODS

Sixty scans (20 scans/provider) of a standard reference cast were made by three different providers using the CEREC Omnicam with both CEREC Ortho 1.2.1 software (10 scans/provider) and CEREC SW 4.4.4 software (10 scans/provider). A digital full arch scan and the time to complete each scan were recorded. Trueness was calculated by overlaying the digital scans against a reference file created using the standard reference cast and a laboratory-based, white light, 3-dimensional scanner. Precision was calculated by overlaying each of digital scans against each other, using each scan as a reference. The non-parametric Mann-Whitney U-test was used to determine significant differences attributable to scanning software for each provider.

RESULTS

The CEREC Ortho 1.2.1 software required a longer scan time than the CEREC SW 4.4.4 software for each provider (∼1 minute). No significant difference in trueness was observed within one provider. Two individual providers had higher precision when scanning with the CEREC Ortho 1.2.1 software than the CEREC SW 4.4.4 software.

CONCLUSION

Software and scan strategy may affect the accuracy of complete-arch scans. The CEREC Ortho 1.2.1 software may demonstrate a speed-accuracy tradeoff, with generally longer scan times and possibly more precise scans.

摘要

目的

本体外研究的目的是评估软件对使用 CEREC Omnicam 进行数字化扫描的扫描时间、准确性和精密度的影响。

材料与方法

由三位不同的操作人员使用 CEREC Omnicam 对标准参照模型进行 60 次扫描(每位操作人员各扫描 20 次),其中 10 次使用 CEREC Ortho 1.2.1 软件,10 次使用 CEREC SW 4.4.4 软件。记录每次扫描的数字化全牙弓扫描和完成扫描所需的时间。通过将数字扫描与使用标准参照模型创建的参考文件进行叠加来计算准确性,以及使用实验室白光三维扫描仪进行叠加来计算精密度。使用非参数曼-惠特尼 U 检验来确定每个操作人员使用不同扫描软件时归因于扫描软件的显著差异。

结果

CEREC Ortho 1.2.1 软件在每位操作人员的扫描时间都比 CEREC SW 4.4.4 软件长(约 1 分钟)。在同一位操作人员中,准确性没有观察到显著差异。两位个别操作人员在使用 CEREC Ortho 1.2.1 软件扫描时的精密度比使用 CEREC SW 4.4.4 软件高。

结论

软件和扫描策略可能会影响全牙弓扫描的准确性。CEREC Ortho 1.2.1 软件可能表现出速度-准确性的权衡,通常扫描时间更长,并且可能具有更精确的扫描。