Garcia Stephanie Suzanne S, Santiago Alvina Pauline D, Directo Princess Mae C
Eye Institute, St. Luke's Medical Center, Quezon City, Philippines.
Curr Eye Res. 2021 Nov;46(11):1768-1776. doi: 10.1080/02713683.2021.1916038. Epub 2021 Apr 19.
: Photographic Hirschberg test applications are practical options for screening in areas where a specialist is not available. A semi-automated Hirschberg test-based application was developed and evaluated on its ability to detect and measure strabismus at distance and near fixation.: This is a prospective cross-sectional inter-rater agreement study conducted at a tertiary hospital. Study A evaluated the ability of the application to determine the presence or absence of strabismus in subjects of unknown strabismus status (n = 28). Study B evaluated the ability of the application to measure the deviation of strabismic subjects (n = 8). All subjects underwent alternate prism cover test (APCT) at distance and near fixation. Facial photographs at distance and near fixation were taken. Each photograph underwent automated face and eye detection, manual limbus and corneal reflex identification, and strabismus detection and measurement.: The application obtained a matching rate of 95.14% for the face and eyes. The application yielded a sensitivity of 92.86% for horizontal strabismus at distance and near fixation, however, with low specificity values (7.692%, 14.81%, and 8%). The Bland-Altman plots derived from Study B showed bias values of application measurements between 3.625Δ and 6.125Δ with wide intervals of the limits of agreement. Repeatability of the measurements yielded bias values of -0.625Δ and 2.5Δ for horizontal and vertical strabismus at distance and 4.375Δ and 1.25Δ at near fixation, respectively.: This semi-automated Hirschberg test-based application can effectively determine the face and eye location and shows potential as a screening tool for horizontal strabismus.
对于在没有专科医生的地区进行筛查而言,基于照片的 Hirschberg 试验应用是切实可行的选择。我们开发了一种基于半自动 Hirschberg 试验的应用程序,并对其在远距离和近距离注视时检测和测量斜视的能力进行了评估。
这是一项在三级医院进行的前瞻性横断面评估者间一致性研究。研究 A 评估了该应用程序在斜视状态未知的受试者(n = 28)中确定是否存在斜视的能力。研究 B 评估了该应用程序测量斜视受试者(n = 8)斜视度的能力。所有受试者均在远距离和近距离注视下接受交替棱镜遮盖试验(APCT)。拍摄了远距离和近距离注视时的面部照片。每张照片都经过了自动面部和眼睛检测、手动角膜缘和角膜反射识别以及斜视检测和测量。
该应用程序对面部和眼睛的匹配率为 95.14%。该应用程序在远距离和近距离注视时对水平斜视的敏感性为 92.86%,然而,特异性值较低(分别为 7.692%、14.81%和 8%)。研究 B 得出的 Bland-Altman 图显示,应用程序测量的偏差值在 3.625Δ 和 6.125Δ 之间,一致性界限的区间较宽。测量的重复性得出,远距离水平和垂直斜视的偏差值分别为 -0.625Δ 和 2.5Δ,近距离注视时分别为 4.375Δ 和 1.25Δ。
这种基于半自动 Hirschberg 试验的应用程序可以有效地确定面部和眼睛的位置,并显示出作为水平斜视筛查工具的潜力。