使用远距离克里姆斯基试验测量斜视角度。

Measurement of strabismic angle using the distance Krimsky test.

作者信息

Joo Kwang Sic, Koo Hyun, Moon Nam Ju

机构信息

Department of Ophthalmology, Chung-Ang University Hospital, Seoul, Korea.

出版信息

Korean J Ophthalmol. 2013 Aug;27(4):276-81. doi: 10.3341/kjo.2013.27.4.276. Epub 2013 Jul 18.

Abstract

PURPOSE

To evaluate the correlation of the distance Krimsky test and the alternate prism cover test (APCT) for the distance deviation in patients with horizontal strabismus.

METHODS

Forty patients with horizontal strabismus (20 esotropia and 20 exotropia) were included in this study. Patients with a variable angle of deviation, vertical angle over 5 prism diopters, impaired binocular vision, or poor cooperation were excluded. We instructed the patient to look a target 6 meters away, and applied a prism over the patient's dominant eye while flashing a light source 33 centimeters from the middle of both eyebrows. When the corneal light reflexes were located on the center of each cornea, we measured the angle of deviation. We defined this method as 'distance Krimsky test,' and the angle measured by this method was compared with the conventional Krimsky test and APCT at distance. We analyzed the accuracy and intra- and inter-observer reliability.

RESULTS

The angle of strabismus measured by the distance Krimsky test showed a significant agreement and correlation with the deviation angle measured by the APCT. We elicited the correlation gradient between the angle measured by the distance Krimsky test and the APCT. In addition, the distance Krimsky test showed significant intra- and inter-observer reliabilities.

CONCLUSIONS

The distance Krimsky test is expected to be more useful than the Krimsky test in measuring the distance angle of deviation for patients with strabismus in whom it is difficult to measure the angle of deviation using the APCT. The distance Krimsky test can be an accurate and useful test through the improvement of proficiency of examiners and the establishment of individualized normative data.

摘要

目的

评估在水平斜视患者中,远距离克里姆斯基试验(Krimsky test)与交替棱镜遮盖试验(APCT)测量远距离斜视度的相关性。

方法

本研究纳入40例水平斜视患者(20例内斜视和20例外斜视)。排除斜视度变化、垂直斜视度超过5棱镜度、双眼视功能受损或配合不佳的患者。我们指导患者注视6米外的目标,在患者优势眼前放置棱镜,同时在两眼眉中间33厘米处闪烁光源。当角膜反光位于各角膜中央时,测量斜视度。我们将此方法定义为“远距离克里姆斯基试验”,并将该方法测量的斜视度与传统克里姆斯基试验及远距离APCT测量的斜视度进行比较。我们分析了其准确性以及观察者内和观察者间的可靠性。

结果

远距离克里姆斯基试验测量的斜视度与APCT测量的斜视度之间显示出显著的一致性和相关性。我们得出了远距离克里姆斯基试验测量的斜视度与APCT测量的斜视度之间的相关梯度。此外,远距离克里姆斯基试验显示出显著的观察者内和观察者间可靠性。

结论

对于难以使用APCT测量斜视度的斜视患者,远距离克里姆斯基试验在测量远距离斜视度方面预计比克里姆斯基试验更有用。通过提高检查者的熟练程度和建立个体化规范数据,远距离克里姆斯基试验可以成为一种准确且有用的检查方法。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c248/3730070/af95a258cf0e/kjo-27-276-g001.jpg