评价多发性硬化症患者的长距离行走能力:6 分钟步行试验中时空行走变量的可靠性。

Evaluation of Prolonged Walking in Persons with Multiple Sclerosis: Reliability of the Spatio-Temporal Walking Variables during the 6-Minute Walk Test.

机构信息

Laboratory of Clinical Functional Exploration of Movement, University Hospital of Besançon, F-25000 Besançon, France.

Clinical Investigation Center, University Hospital of Besançon, INSERM 1431, F-25000 Besançon, France.

出版信息

Sensors (Basel). 2021 Apr 28;21(9):3075. doi: 10.3390/s21093075.

Abstract

BACKGROUND

Walking disorders represent the most disabling condition in persons with Multiple Sclerosis (PwMS). Several studies showed good reliability of the 6-min walk test (6MWT) (i.e., especially distance traveled), but little is known about the reliability of the Spatio-temporal (ST) variables in the 6MWT.

OBJECTIVE

To evaluate the test-retest reliability of ST variables and perceived exertion during the 6MWT in PwMS and comparable healthy persons.

METHODS

We explored three 1-min intervals (initial: 0'-1', middle: 2'30″-3'30″, end: 5'-6') of the 6MWT. Six ST variables and perceived exertion were measured (respectively, using the GAITRite system and the Borg Scale). These measurements were performed twice, 1 week apart. The test-retest effects were assessed using the intraclass correlation coefficient (ICC) or the weighted kappa.

RESULTS

Forty-five PwMS and 24 healthy persons were included. The test-retest reliability of ST variables values was good-to-excellent for PwMS (ICC range: 0.858-0.919) and moderate-to-excellent for healthy persons (ICC range: 0.569-0.946). The test-retest reliability values of perceived exertion were fair for PwMS (weighted kappa range: 0.279-0.376) and substantial for healthy persons (weighted kappa range: 0.734-0.788).

CONCLUSION

The measurement of ST variables during these 6MWT intervals is reliable and applicable in clinical practice and research to adapt rehabilitation care in PwMS.

摘要

背景

行走障碍是多发性硬化症患者(PwMS)最致残的症状。多项研究表明,6 分钟步行测试(6MWT)的距离(即行走距离)具有良好的可靠性,但关于 6MWT 时空(ST)变量的可靠性知之甚少。

目的

评估多发性硬化症患者和可比健康人在 6MWT 中 ST 变量和感知用力的测试-重测信度。

方法

我们探索了 6MWT 的三个 1 分钟区间(初始:0'-1',中间:2'30″-3'30″,结束:5'-6')。分别使用步态分析系统和 Borg 量表测量了 6 个 ST 变量和感知用力。这些测量在 1 周内进行两次。使用组内相关系数(ICC)或加权kappa 评估测试-重测效果。

结果

纳入了 45 名多发性硬化症患者和 24 名健康人。多发性硬化症患者的 ST 变量值的测试-重测可靠性为良好至优秀(ICC 范围:0.858-0.919),健康人的测试-重测可靠性为中度至优秀(ICC 范围:0.569-0.946)。多发性硬化症患者的感知用力测试-重测可靠性为适度至优秀(加权 kappa 范围:0.279-0.376),健康人的测试-重测可靠性为实质性(加权 kappa 范围:0.734-0.788)。

结论

在这些 6MWT 区间内测量 ST 变量是可靠的,可在临床实践和研究中应用,以调整多发性硬化症患者的康复护理。