Liu Bonan, Yang Kaiming, Liao Changrui, Cai Zhihao, Liu Yifan, Sun Bing, Wang Yiping
Opt Lett. 2021 May 1;46(9):2204-2207. doi: 10.1364/OL.424581.
Localized tilted fiber Bragg gratings (TFBGs) with low insertion loss are reported. A series of second-order TFBGs with tilt angles of 0°, 7°, 14°, and 21° was inscribed line by line directly in a single-mode fiber. For the 7° TFBG, the Bragg resonance was 2.4 dB at 1550 nm, and the maximum cladding-mode resonance reached 24.6 dB with an insertion loss of 0.8 dB, the same level as that for TFBGs fabricated by the phase-mask method. The range in cladding-mode resonance for the TFBGs obtained was wider than 170 nm with an intensity exceeding 20 dB. Combined with microscope images, the formation of these localized TFBGs and their spectral performance are discussed. The effect of an inscription offset along the $y$-axis direction was further investigated. With increasing offset, the intensity of the cladding-mode resonance dropped rapidly. The refractive index response sensitivity of the 7° TFBG was measured at 507.54 nm/RIU.