Abstract

BACKGROUND

Cardiovascular disease is the most common cause of death after kidney transplantation. Coronary artery disease (CAD) assessment is therefore mandatory in patients evaluated for transplantation. We aimed to assess the diagnostic accuracy for CAD of single-photon emission computed tomography (SPECT) compared to the standards invasive coronary angiography (ICA) and coronary computed tomography angiography (CCTA) in patients evaluated for kidney transplantation.

METHODS

We performed a systematic literature search in PubMed, EMBASE, Web of Science, OvidSP (Medline), The Cochrane Library and Google Scholar. Studies investigating the diagnostic accuracy of myocardial perfusion imaging (MPI) SPECT in patients evaluated for kidney transplantation were retrieved. After a risk of bias assessment using QUADAS-2, a meta-analysis was conducted.

RESULTS

Out of 1459 records, 13 MPI SPECT studies were included in the meta-analysis with a total of 1245 MPI SPECT scans. There were no studies available with CCTA as reference. Pooled sensitivity of MPI SPECT for CAD was 0.66 (95% CI 0.53 to 0.77), pooled specificity was 0.75 (95% CI 0.63 to 0.84) and the area under the curve (AUC) was 0.76. Positive likelihood ratio was 2.50 (95% CI 1.78 to 3.51) and negative likelihood ratio was 0.41 (95% CI 0.28 to 0.61). Pooled positive predictive value was 64.9% and pooled negative predictive value was 74.1%. Significant heterogeneity existed across the included studies.

CONCLUSIONS

MPI SPECT had a moderate diagnostic accuracy in patients evaluated for kidney transplantation, with a high rate of false-negative findings. The use of an anatomical gold standard against a functional imaging test in the included studies is however suboptimal.

摘要

背景

心血管疾病是肾移植后最常见的死亡原因。因此,在评估肾移植患者时,必须对冠状动脉疾病(CAD)进行评估。我们旨在评估单光子发射计算机断层扫描(SPECT)对 CAD 的诊断准确性,与标准的有创冠状动脉造影(ICA)和冠状动脉计算机断层扫描血管造影(CCTA)在评估肾移植的患者中的诊断准确性进行比较。

方法

我们在 PubMed、EMBASE、Web of Science、OvidSP(Medline)、The Cochrane Library 和 Google Scholar 中进行了系统文献检索。检索了评估肾移植患者的心肌灌注成像(MPI)SPECT 的诊断准确性的研究。使用 QUADAS-2 进行风险偏倚评估后,进行了荟萃分析。

结果

在 1459 条记录中,有 13 项 MPI SPECT 研究被纳入荟萃分析,共包括 1245 项 MPI SPECT 扫描。没有 CCTA 作为参考的研究。MPI SPECT 对 CAD 的汇总敏感性为 0.66(95%CI 0.53 至 0.77),汇总特异性为 0.75(95%CI 0.63 至 0.84),曲线下面积(AUC)为 0.76。阳性似然比为 2.50(95%CI 1.78 至 3.51),阴性似然比为 0.41(95%CI 0.28 至 0.61)。汇总阳性预测值为 64.9%,汇总阴性预测值为 74.1%。纳入的研究之间存在显著的异质性。

结论

MPI SPECT 在评估肾移植患者时具有中等的诊断准确性,但假阴性结果的发生率较高。然而,在纳入的研究中,使用解剖学金标准对抗功能性成像测试是不理想的。