Abstract

We evaluated an automated method for measuring total magnesium in serum, plasma, or urine that utilizes dry multilayered thin-film reagents and reflectance photometry for use on the Kodak Ektachem 400 analyzer. Comparison of magnesium results by this method and by atomic absorption revealed the following: the results on samples from a variety of patients agreed closely, the thin-film methodology was not affected by icteric, hemolyzed, or lipemic samples, and over 100 drugs studied did not interfere. Only very high concentrations of citrate and calcium affected magnesium results by this method. Both the accuracy and versatility of the thin-film method are well suited to routine, fast response, and pediatric testing in the clinical laboratory.

摘要

我们评估了一种用于测量血清、血浆或尿液中总镁含量的自动化方法,该方法使用干式多层薄膜试剂和反射光度法,可在柯达Ektachem 400分析仪上使用。通过该方法与原子吸收法对镁含量结果进行比较,结果如下:来自各类患者的样本结果非常吻合,薄膜法不受黄疸、溶血或脂血样本的影响,且研究的100多种药物均无干扰。只有极高浓度的柠檬酸盐和钙会影响该方法的镁含量结果。薄膜法的准确性和通用性都非常适合临床实验室的常规、快速反应及儿科检测。