Suppr超能文献

应用声辐射力脉冲弹性成像技术评估健康志愿者胸腰筋膜弹性标准值:一项横断面研究。

Elasticity standard values of the thoracolumbar fascia assessed with acoustic radiation force impulse elastography on healthy volunteers: A cross section study.

作者信息

Wakker Jonas, Kratzer Wolfgang, Schmidberger Julian, Graeter Tilmann

机构信息

Department of General, Thoracic and Vascular Surgery, Triemli City Hospital, Birmensdorferstrasse 497, 8063, Zurich, Switzerland.

Department of Internal Medicine I, University Hospital Ulm, Albert-Einstein-Allee 23, 89081, Ulm, Germany.

出版信息

J Bodyw Mov Ther. 2021 Apr;26:530-537. doi: 10.1016/j.jbmt.2020.10.017. Epub 2020 Oct 26.

Abstract

INTRODUCTION

Determining the normal values for acoustic radiation force impulse (ARFI) shear wave elastography of the thoracolumbar fascia (TLF) and define possible factors of influence.

METHODS

We measured the shear wave velocity (SWV) in m/s and the diameter (anterior-posterior) in mm of the TLF bilateral in 267 healthy participants with the Acuson S3000™ (Siemens) using the virtual touch image quantification mode (VTIQ). The parameters were tested for correlations with the anthropometric data of the participants, between different age groups and the genders, as well as information obtained from the history, such as smoking and sporting activities.

RESULTS

We determined a mean SWV of 3.28 ± 0.55 m/s for the left thoracolumbar fascia and 3.44 ± 0.55 m/s for the right. The diameter on the right was 2.7 ± 0.8 mm. On the left, it was 2.7 ± 0.9 mm. Neither body mass index (BMI) nor gender had a significant effect on either of the measured parameters (p > 0.05). The same goes for regular medication, sporting activity or the consumption of alcohol (p > 0.05). The results concerning the effect of smoking and age were inconclusive as they only had a significant influence to either the right or the left side of the TLF but not on the other side.

CONCLUSIONS

We collected the normal value for ARFI shear wave elastography of the TLF in 267 healthy participants. Furthermore, neither gender, BMI, sports activity nor the consumption of alcohol affected the elasticity or the diameter of the thoracolumbar fascia.

摘要

引言

确定胸腰筋膜(TLF)的声辐射力脉冲(ARFI)剪切波弹性成像的正常值,并确定可能的影响因素。

方法

我们使用虚拟触诊成像定量模式(VTIQ),通过西门子Acuson S3000™对267名健康参与者双侧胸腰筋膜的剪切波速度(SWV,单位为m/s)和直径(前后径,单位为mm)进行测量。测试这些参数与参与者人体测量数据、不同年龄组和性别之间的相关性,以及从病史中获得的信息,如吸烟和体育活动情况。

结果

我们确定左侧胸腰筋膜的平均SWV为3.28±0.55 m/s,右侧为3.44±0.55 m/s。右侧直径为2.7±0.8 mm,左侧为2.7±0.9 mm。体重指数(BMI)和性别对任何一个测量参数均无显著影响(p>0.05)。常规用药、体育活动或饮酒情况对测量参数也无显著影响(p>0.05)。关于吸烟和年龄影响的结果尚无定论,因为它们仅对胸腰筋膜的右侧或左侧有显著影响,对另一侧无影响。

结论

我们收集了267名健康参与者胸腰筋膜ARFI剪切波弹性成像的正常值。此外,性别、BMI、体育活动或饮酒均未影响胸腰筋膜的弹性或直径。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验