Suppr超能文献

造影剂诱发的心室颤动。泛影葡胺-76、碘克沙醇和欧乃派克的比较。

Contrast media-induced ventricular fibrillation. A comparison of Hypaque-76, Hexabrix, and Omnipaque.

作者信息

Piao Z E, Murdock D K, Hwang M H, Raymond R M, Scanlon P J

机构信息

Department of Medicine, Hines Veterans Administration Hospital, IL 60141.

出版信息

Invest Radiol. 1988 Jun;23(6):466-70. doi: 10.1097/00004424-198806000-00010.

Abstract

Contrast media occasionally produce ventricular fibrillation during coronary angiography. We compared the fibrillatory propensity of the conventional ionic contrast medium, Hypaque-76 (H76) to the low osmolar ionic dimer Hexabrix (HB) and to the nonionic agent Omnipaque (OM) in 20 open chest anesthetized dogs. Intracoronary injection of 6 mL of contrast medium produced spontaneous ventricular fibrillation in four of ten dogs with H76, compared with two of ten with HB, and zero of ten with OM (P = .07). The induction of two premature beats by programmed stimulation of the myocardium during injection of 4 mL of contrast medium produced ventricular fibrillation in ten of ten dogs with H76, compared with three of ten with HB, and zero of ten with OM (P less than .001). Both H76 and HB produced ventricular fibrillation in ten of ten dogs when three premature beats were induced, compared with two of ten dogs with OM (P less than .001). Four mL H76 produced a 109 +/- 18 msec increase in the QT interval, compared with an 82 +/- 17 msec increase with HB, and a 45 +/- 12 msec increase with OM. We conclude that both low osmolar HB and OM are less fibrillatory than the conventional ionic medium H76, and that the nonionic medium OM is less fibrillatory than the ionic dimer contrast medium HB.

摘要

造影剂在冠状动脉造影过程中偶尔会引发心室颤动。我们在20只开胸麻醉犬中比较了传统离子型造影剂泛影葡胺-76(H76)、低渗离子二聚体碘克沙醇(HB)和非离子型造影剂欧乃派克(OM)引发心室颤动的倾向。冠状动脉内注射6毫升造影剂后,10只使用H76的犬中有4只出现自发性心室颤动,而使用HB的10只犬中有2只出现,使用OM的10只犬中无一出现(P = 0.07)。在注射4毫升造影剂期间通过程控刺激心肌诱发两个早搏后,10只使用H76的犬中有10只出现心室颤动,而使用HB的10只犬中有3只出现,使用OM的10只犬中无一出现(P < 0.001)。当诱发三个早搏时,使用H76和HB的10只犬中有10只出现心室颤动,而使用OM的10只犬中有2只出现(P < 0.001)。4毫升H76使QT间期延长109±18毫秒,而HB使其延长82±17毫秒,OM使其延长45±12毫秒。我们得出结论,低渗的HB和OM引发心室颤动的可能性均低于传统离子型造影剂H76,且非离子型造影剂OM引发心室颤动的可能性低于离子二聚体造影剂HB。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验