Suppr超能文献

各种计算机断层扫描协议中所接受的有效剂量评估及其影响因素

Assessment of Effective Dose Received in Various Computed Tomography Protocols and Factors Affecting It.

作者信息

Kumar Vikrant, Tayal Sachin, Ali Abbas, Gandhi Arun

机构信息

Department of Nuclear Medicine, Kailash Cancer Hospital and Research Centre, Muni Seva Ashram, Vadodara, Gujarat, India.

出版信息

Indian J Nucl Med. 2021 Jan-Mar;36(1):32-38. doi: 10.4103/ijnm.IJNM_112_20. Epub 2021 Mar 4.

Abstract

PURPOSE OF STUDY

The purpose of the study was to evaluate the effect of patient characteristics and equipment-related factors on the computed tomography (CT) dose received by patients from positron emission tomography-CT (PET-CT) using system-generated dose-length product (DLP) values and also to check the effective dose (ED) received from various CT protocols at our institute.

MATERIALS AND METHODS

This retrospective study included 78 adult patients who underwent F-18 fluorodeoxyglucose whole-body PET-CT and were divided into three groups based on the area of primary cancerous lesion. In Group A, we had 44 patients who underwent PET-CT (head-and-neck protocol), in Group B, we had 24 patients who underwent PET-CT (whole body with brain protocol), and in Group C, we had 10 patients who underwent PET-CT (pelvis protocol). All of the patients under the study are of South Asian ethnicity. A majority of patients 53.85% were males and remaining 46.15% were females. The product of conversion factor (k-coefficient), as described in "American Association of Physicists in Medicine Report No. 96" and DL value generated by the scanner, was used to calculate the ED. Moreover, we also performed regression analysis to check relation between body weight, height, scan range, tube current, Volume computed tomography dose index (CTDIvol), DLP, and ED.

RESULTS

The regression analysis shows that scan range, patient height, weight, tube current, and DLP were significantly correlated with ED ( < 0.05 for all). Moreover, the DLP and conversion factor method estimated the ED from various groups. Patients under Group A (head-and-neck protocol), Group B (whole body with brain protocol), Group C (pelvis protocol) received an average ED of 22.45 mSv, 22.40 mSv, and 21.24 mSv, respectively.

CONCLUSION

ED from CT component of PET-CT can be assessed as the product of scanner-generated DLP and conversion factor for selected range. Moreover, body weight, scan range, and tube current had an independent significant effect on ED received from CT.

摘要

研究目的

本研究的目的是利用系统生成的剂量长度乘积(DLP)值评估患者特征和设备相关因素对患者接受正电子发射断层扫描-计算机断层扫描(PET-CT)的计算机断层扫描(CT)剂量的影响,并检查我院各种CT检查方案下患者接受的有效剂量(ED)。

材料与方法

这项回顾性研究纳入了78例接受F-18氟脱氧葡萄糖全身PET-CT检查的成年患者,并根据原发性癌灶的部位分为三组。A组有44例接受PET-CT(头颈方案)的患者,B组有24例接受PET-CT(包括脑部的全身方案)的患者,C组有10例接受PET-CT(骨盆方案)的患者。研究中的所有患者均为南亚族裔。大多数患者(53.85%)为男性,其余46.15%为女性。采用《美国医学物理学家协会第96号报告》中所述的转换因子(k系数)与扫描仪生成的DL值的乘积来计算ED。此外,我们还进行了回归分析,以检查体重、身高、扫描范围、管电流、容积计算机断层扫描剂量指数(CTDIvol)、DLP和ED之间的关系。

结果

回归分析表明,扫描范围、患者身高、体重、管电流和DLP与ED显著相关(均P<0.05)。此外,DLP和转换因子法估计了各组的ED。A组(头颈方案)、B组(包括脑部的全身方案)、C组(骨盆方案)的患者平均接受的ED分别为22.45 mSv、22.40 mSv和21.24 mSv。

结论

PET-CT的CT部分的ED可以通过扫描仪生成的DLP与选定范围的转换因子的乘积来评估。此外,体重、扫描范围和管电流对CT接受的ED有独立的显著影响。