Suppr超能文献

基于图像配准和轴向角表示法的肩锁关节矢状面运动姿势分析

Analysis of the Sagittal Motion Posture of the Acromioclavicular Joint Using Image Registration and Axial Angle Representation.

作者信息

Su Peng, Zhou Jun-Lin, Yun Cai, Liu Feng, Zhang Yi

机构信息

Department of Orthopaedics, Teaching Hospital of Capital Medical University, Beijing Shijingshan Hospital, Beijing, People's Republic of China.

Department of Orthopedics, Beijing Chaoyang Hospital, Capital Medical University, Beijing, People's Republic of China.

出版信息

Int J Gen Med. 2021 May 20;14:1975-1981. doi: 10.2147/IJGM.S302938. eCollection 2021.

Abstract

OBJECTIVE

This study aimed to directly and accurately measure the range of motion of the acromioclavicular joint through 3D reconstruction and image registration.

METHODS

Thirteen healthy volunteers participated in the study. Computerized tomography (CT) was used to measure the acromioclavicular joint in four different motion poses. The images were integrated using reconstruction and registration technology, and the rotation angle range of the acromioclavicular joint was measured using 3D reconstruction. The measurements were expressed by axial angle representation. The dominant and the non-dominant sides were compared, and the difference in the axial angle of the acromioclavicular joint was compared in different postures.

RESULTS

The difference between the dominant and non-dominant sides in acromioclavicular motion was not significant. In the sagittal motion of the upper limb, the rotation angle of the acromioclavicular joint was greatest in a resting horizontal position, with an average of 26.1°. In this position, 34.6% of flexion and extension movements of the upper limb were completed by the acromioclavicular joint, which was the highest level of engagement. The rotation angle was lowest in the resting posteroinferior position, with an average of 8.2°. In this position, 24.9% of the flexion and extension movements of the upper limb were completed by the acromioclavicular joint.

CONCLUSION

Combining 3D reconstruction and image registration is a direct and accurate method of measuring the motion of the acromioclavicular joint. The rotational motions of the acromioclavicular joint are bilaterally symmetrical and can be used as a reference for comparative study. The maximum range of motion of the acromioclavicular joint during rotation was found in the resting horizontal position. The clinical examination and post-treatment evaluation of the acromioclavicular joint's rotation function can therefore be targeted in this range.

摘要

目的

本研究旨在通过三维重建和图像配准直接、准确地测量肩锁关节的活动范围。

方法

13名健康志愿者参与了本研究。使用计算机断层扫描(CT)在四种不同运动姿势下测量肩锁关节。利用重建和配准技术整合图像,并使用三维重建测量肩锁关节的旋转角度范围。测量结果用轴向角表示。比较优势侧和非优势侧,并比较不同姿势下肩锁关节轴向角的差异。

结果

肩锁关节运动中优势侧与非优势侧的差异不显著。在上肢矢状面运动中,肩锁关节在静息水平位时旋转角度最大,平均为26.1°。在此位置,上肢屈伸运动的34.6%由肩锁关节完成,这是参与度最高的水平。旋转角度在静息后下位时最低,平均为8.2°。在此位置,上肢屈伸运动的24.9%由肩锁关节完成。

结论

结合三维重建和图像配准是测量肩锁关节运动的一种直接、准确的方法。肩锁关节的旋转运动双侧对称,可作为比较研究的参考。发现肩锁关节在旋转过程中的最大活动范围出现在静息水平位。因此,肩锁关节旋转功能的临床检查和治疗后评估可针对此范围进行。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3eb7/8144179/b05400a2f0ed/IJGM-14-1975-g0001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验