Department of Laboratory Medicine, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, Korea.
Department of Laboratory Medicine, Seoul National University College of Medicine, Seoul, Korea.
J Korean Med Sci. 2021 May 31;36(21):e158. doi: 10.3346/jkms.2021.36.e158.
The antibody titer of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was observed in 289 healthy healthcare workers who had completed the second dose of the Pfizer-BioNTech coronavirus disease 2019 (COVID-19) vaccine. Antibody tests were performed using both the automated electrochemiluminescence immunoassay (ECLIA) and the chromatographic lateral flow immunoassay (LFIA). All subjects had antibodies against the receptor binding domain of the spike protein of SARS-CoV-2 only one week after completing the vaccination, and the antibody titer became significantly higher after another week ( < 0.001). Since there was a large amount of antibody formation within two weeks after completion of vaccination, the less sensitive method, LFIA, also showed high sensitivity. There was no significant difference between whole blood and serum in detecting SARS-CoV-2 antibodies after vaccination. This is an early study of vaccinations among Koreans and is expected to contribute to the establishment of national guidelines on COVID-19 vaccination.
对 289 名已完成辉瑞-生物技术公司 2019 年冠状病毒病(COVID-19)疫苗第二剂接种的健康医护人员的严重急性呼吸综合征冠状病毒 2(SARS-CoV-2)抗体滴度进行了观察。使用自动化电化学发光免疫分析(ECLIA)和色谱侧向流动免疫分析(LFIA)进行抗体检测。所有受试者在接种疫苗后仅一周即对 SARS-CoV-2 刺突蛋白受体结合域产生抗体,并且在又一周后抗体滴度显著升高(<0.001)。由于在接种完成后两周内形成了大量抗体,因此较不敏感的方法 LFIA 也显示出了较高的灵敏度。接种疫苗后,全血和血清在检测 SARS-CoV-2 抗体方面没有差异。这是一项针对韩国人的早期疫苗接种研究,有望为制定 COVID-19 疫苗接种国家指南做出贡献。