Suppr超能文献

足底筋膜的剪切波弹性成像:足底筋膜炎患者与健康对照者的比较

Shear Wave Elastography of the Plantar Fascia: Comparison between Patients with Plantar Fasciitis and Healthy Control Subjects.

作者信息

Baur Daniel, Schwabl Christoph, Kremser Christian, Taljanovic Mihra S, Widmann Gerlig, Sconfienza Luca Maria, Sztankay Judith, Feuchtner Gudrun, Klauser Andrea S

机构信息

Radiology Department, Medical University Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria.

Banner University Medical Center, Department of Medical Imaging, College of Medicine, The University of Arizona, Tucson, AZ 85724, USA.

出版信息

J Clin Med. 2021 May 27;10(11):2351. doi: 10.3390/jcm10112351.

Abstract

BACKGROUND

The purpose of this study was to evaluate plantar fasciae of healthy subjects and patients with plantar fasciitis by shear wave velocity (SWV) and stiffness with correlation to B-Mode and color Doppler ultrasonography (CDUS) and to establish cut-off values.

METHODS

This observational study was conducted with the approval of the Institutional Review Boards (IRBs) of our institution. 108 unilateral plantar fasciae were evaluated by including 87 consecutive patients (mean age 51.7; range: 29-82) (66 women and 21 men) with plantar fasciitis and 21 asymptomatic age matched healthy volunteers (mean age 47.3; range: 32-58) (15 women and 6 men). All patients were prospectively imaged between July 2018 and March 2019. B-mode US was used to measure thickness and CDUS to grade vascularity. SWE measurements were repeated 3 times and mean was used for statistical analysis.

RESULTS

Mean SWV value in healthy subjects was 6.94 m/s and in patients 4.98 m/s with a mean stiffness value of 152.88 kPa and 93.54 kPa respectively ( < 0.001). For SWV a cut-off value of 6.16 m/s had a specificity of 80.95% and sensitivity of 79.31%. For stiffness a cut-off value of 125.57 kPa had a specificity of 80.95% and sensitivity of 80.46%. No correlation to CDUS was found. The mean thickness of healthy fascias was 3.3 mm (range 2.4-3.9) compared to 6.1 mm (range 2.0-22.0) in plantar fasciitis ( < 0.001) with no correlation to SWV or to stiffness (r² = 0.02, = 0.06).

CONCLUSION

SWE allows quantitative assessment of plantar fascia stiffness, which decreases in patients with plantar fasciitis. No correlation to the thickness of the plantar fascia was found, therefore it represents an independent factor for the diagnosis of plantar fasciitis and could be helpful in addition to thickness measurement in unclear cases.

摘要

背景

本研究旨在通过剪切波速度(SWV)和硬度评估健康受试者及足底筋膜炎患者的足底筋膜,并与B超和彩色多普勒超声(CDUS)相关联,以确定临界值。

方法

本观察性研究经本机构机构审查委员会(IRB)批准。纳入87例连续的足底筋膜炎患者(平均年龄51.7岁;范围:29 - 82岁)(66名女性和21名男性)和21名年龄匹配的无症状健康志愿者(平均年龄47.3岁;范围:32 - 58岁)(15名女性和6名男性),对108侧单侧足底筋膜进行评估。所有患者于2018年7月至2019年3月期间进行前瞻性成像。使用B超测量厚度,CDUS评估血管分布情况。剪切波弹性成像(SWE)测量重复3次,取平均值用于统计分析。

结果

健康受试者的平均SWV值为6.94 m/s,患者为4.98 m/s,平均硬度值分别为152.88 kPa和93.54 kPa(<0.001)。对于SWV,临界值为6.16 m/s时,特异性为80.95%,敏感性为79.31%。对于硬度,临界值为125.57 kPa时,特异性为80.95%,敏感性为80.46%。未发现与CDUS相关。健康筋膜的平均厚度为3.3 mm(范围2.4 - 3.9),而足底筋膜炎患者为6.1 mm(范围2.0 - 22.0)(<0.001),与SWV或硬度均无相关性(r² = 0.02,= 0.06)。

结论

SWE可对足底筋膜硬度进行定量评估,足底筋膜炎患者的足底筋膜硬度降低。未发现与足底筋膜厚度相关,因此它是诊断足底筋膜炎的一个独立因素,在诊断不明确的病例中,除测量厚度外可能会有帮助。