Nogueira Daiane, Bueno Carlos Eduardo Da Silveira, Kato Augusto Shoji, Martin Alexandre Sigrist De, Pelegrine Rina Andréa, Limoeiro Ana Grasiela Da Silva, Rocha Daniel Guimarães Pedro, Fontana Carlos Eduardo
Department of Endodontics São Leopoldo Mandic Dental Research Center, School of Dentistry, Ilhéus, Bahia, Brazil.
Department of Endodontics, School of Dentistry, Ilhéus, Bahia, Brazil.
J Conserv Dent. 2020 Nov-Dec;23(6):554-557. doi: 10.4103/JCD.JCD_117_19. Epub 2021 Feb 11.
It is essential to know if the immersion in sodium hypochlorite (NaOCl) influences the cyclic fatigue resistance of nickel-titaniumm (NiTi) files.
This study was aimed to evaluate the resistance to the cyclic fatigue of three NiTi systems, as well as the influence of 5.25% NaOCl on their resistance.
Files from the Sequence Rotary File (MK life, Porto Alegre, Brazil), ProTaper Next (PTN) (Dentsply, Maillefer, Baillagues, Switzerland), and HyFlex EDM (Coltène Whaledent, Allstatten, Switzerland) systems were tested and separated into Group 1)-without immersion in NaOCl solution and Group 2 and Group 3-immersed in 5.25% NaOCl solution, for 1 min, and 5 min, respectively. All instruments were submitted to the cyclic fatigue test. Images of the instruments were observed by scanning electron microscopy, to evaluate the type of defect presented on the fractured surface. The test performed for the analysis of two independent factors was a two-way analysis of variance.
HyFlex EDM presented a greater number of cycles until fracture when compared to others ( < 0.001). The control group showed a greater number of cycles until fracture than the same instruments submitted to NaOCl ( < 0.001). Sequence instruments showed the lowest values of cycles until fracture ( < 0.001). There was no statistically significant difference between treatments ( = 0.998). PTN, showed intermediate values of fracture resistance when compared to the HyFlex EDM and sequence instruments ( < 0.001), but without intragroup differences ( = 0.437).
Hyflex EDM instruments were the most resistant to cyclic fatigue.