Hypersensitivity reactions are suspected to cause premature aseptic loosening in susceptible patients after total knee arthroplasty. In response, metal-free implants have been developed. The aim of this prospective, observational midterm study was the assessment of a completely metal-free ceramic knee replacement system as a concise follow-up of a previous report.
Thirty-eight patients, with anamnestic suspected or documented allergy to the metal used in prosthetic alloys, participated in this 4-year follow-up of the metal-free BPK-S (Peter Brehm) total knee replacement system with ceramic femoral and tibial components. Clinical assessment included Knee Society Score (KSS), Oxford Knee Score, Euro Quol-5D-Visual Analogue Scale (EQ-5D-VAS), and perioperative or postoperative complications and need for revision. The position of the implant, signs of loosening, and leg alignment were assessed radiographically.
All postoperative clinical scores improved significantly from baseline to 48-month follow-up examination. The Oxford Knee Score improved from 39 to 15 points. The KSS improved from 99 to 195 points (the KSS knee score 42.5 to 96 and the KSS function score 60 to 100). The EQ-5D improved from 12 to 7 points; the EQ-VAS improved from 52.5 to 97 points. No allergic reactions could be detected. Radiologically, a median preoperative varus deformity of 5° improved to 0° at 4-year follow-up. Radiolucent lines appeared around uncemented areas with no clinical symptoms.
The fully metal-free BPK-S Integration ceramic knee replacement system exhibits excellent immuno-allergological compatibility, offering a safe option for patients with prior hypersensitivity reactions to metallic materials. Full cementation of all components is recommended to avoid radiolucent lines around the implant.
全膝关节置换术后,敏感患者疑似发生过敏反应导致假体早期无菌性松动。因此,开发了无金属植入物。本前瞻性、观察性中期研究旨在评估一种完全无金属的陶瓷膝关节置换系统,作为之前报告的简短随访。
38 名患者有假体合金中金属过敏的病史或记录,参与了无金属 BPK-S(Peter Brehm)全膝关节置换系统的 4 年随访,该系统采用陶瓷股骨和胫骨组件。临床评估包括膝关节学会评分(KSS)、牛津膝关节评分、欧洲五维健康量表-视觉模拟评分(EQ-5D-VAS)以及围手术期或术后并发症和翻修需求。通过影像学评估植入物的位置、松动迹象和下肢对线。
所有术后临床评分均从基线随访检查显著提高。牛津膝关节评分从 39 分提高到 15 分。KSS 从 99 分提高到 195 分(KSS 膝关节评分从 42.5 分提高到 96 分,KSS 功能评分从 60 分提高到 100 分)。EQ-5D 从 12 分提高到 7 分;EQ-VAS 从 52.5 分提高到 97 分。未检测到过敏反应。影像学上,术前中位数 5°的内翻畸形在 4 年随访时改善至 0°。未固定区域出现透明线,但无临床症状。
完全无金属的 BPK-S Integration 陶瓷膝关节置换系统具有优异的免疫过敏兼容性,为对金属材料过敏的患者提供了安全的选择。建议对所有组件进行全骨水泥固定,以避免植入物周围出现透明线。