计算机辅助设计与制造(CAD-CAM)和热压二硅酸锂全冠的边缘适合性:一项系统评价和荟萃分析

Marginal adaptation of CAD-CAM and heat-pressed lithium disilicate crowns: A systematic review and meta-analysis.

作者信息

Sanches Ingrid Bandeira, Metzker Thayara Coelho, Kappler Roniel, Oliveira Michelle Villa, Carvalho Adriana Oliveira, Castor Xisto Lima Emilena Maria

机构信息

Master, Department of Dentistry, Bahiana School of Medicine and Public Health (EBMSP), Salvador, Bahia, Brazil.

Master student, Department of Dentistry, Bahiana School of Medicine and Public Health (EBMSP), Salvador, Bahia, Brazil.

出版信息

J Prosthet Dent. 2023 Jan;129(1):34-39. doi: 10.1016/j.prosdent.2021.03.021. Epub 2021 Jun 16.

Abstract

STATEMENT OF PROBLEM

Lithium disilicate crowns can be manufactured by computer-aided design and computer-aided manufacturing (CAD-CAM) or with the heat-pressed technique. The outcome of studies comparing the effect of the manufacturing method on the marginal adaptation of these crowns is not clear.

PURPOSE

The purpose of this systematic review and meta-analysis was to investigate the effect of the CAD-CAM system and pressing technique on the marginal adaptation of lithium disilicate crowns.

MATERIAL AND METHODS

This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. A literature research was conducted in MEDLINE via PubMed and Scopus databases, relevant journal sites, and the authors' collected references, from January 2009 to April 2019.

RESULTS

The electronic and manual searches that could be read in full totaled 24 studies; of which, 9 were included in the systematic review and meta-analysis, 7 of which were in vitro and 2 in vivo. Statistical analyses were conducted by using Review Manager software program. Meta-analyses were performed with the random effects model (α=.05). In vitro studies showed no difference in the manufacturing (P>.001; 95% confidence interval -0.687 to 0.632), and no significant difference was found for in vivo studies (P=.7, 95% confidence interval 0.00 to 54.77). In the joint analysis of the in vivo and in vitro articles, there was a significant difference between the manufacturing methods (P<.001).

CONCLUSIONS

Differences were detected between the marginal adaptation of lithium disilicate crowns fabricated with the CAD-CAM system and the pressing technique, but the accuracy values were clinically acceptable.

摘要

问题陈述

二硅酸锂全冠可通过计算机辅助设计与计算机辅助制造(CAD-CAM)或热压技术制造。比较这些全冠制造方法对边缘适合性影响的研究结果尚不清楚。

目的

本系统评价和荟萃分析的目的是研究CAD-CAM系统和热压技术对二硅酸锂全冠边缘适合性的影响。

材料与方法

本研究遵循系统评价和荟萃分析的首选报告项目(PRISMA)声明。于2009年1月至2019年4月通过PubMed和Scopus数据库、相关期刊网站以及作者收集的参考文献在MEDLINE中进行文献检索。

结果

可全文阅读的电子检索和手工检索文献共24项研究;其中9项纳入系统评价和荟萃分析,7项为体外研究,2项为体内研究。使用Review Manager软件程序进行统计分析。采用随机效应模型(α = 0.05)进行荟萃分析。体外研究显示制造方法之间无差异(P>0.001;95%置信区间为-0.687至0.632),体内研究也未发现显著差异(P = 0.7,95%置信区间为0.00至54.77)。在体内和体外文章的联合分析中,制造方法之间存在显著差异(P<0.001)。

结论

采用CAD-CAM系统和热压技术制造的二硅酸锂全冠在边缘适合性方面存在差异,但精度值在临床上是可接受的。