Pacáková V, Stulík K, Príhoda M
Department of Analytical Chemistry, Charles University, Prague 2, Czechoslovakia.
J Chromatogr. 1988 Jun 17;442:147-56. doi: 10.1016/s0021-9673(00)94464-9.
The chromatographic behaviour of eighteen s-triazine derivatives has been studied in a reversed-phase system with a Separon SIC 18 stationary phase and a mobile phase of aqueous sodium dihydrogenphosphate and methanol. The dependences of the capacity factors on the methanol content, the pH and the ionic strength have been obtained. Ultraviolet photometric detection can generally be used whereas amperometric detection with a carbon-fibre array electrode is useful for selective detection of s-triazine hydroxy derivatives, but with a sensitivity poorer than that of photometric detection. The method has been applied to a study of the photolysis of s-triazines and the effect of the substituents and the pH on the photolysis rate.