McLellan G L, Scalapino M C
Department of Radiology, University Hospital of Jacksonville, University of Florida Health Science Center 32209.
Radiology. 1988 Oct;169(1):264-5. doi: 10.1148/radiology.169.1.3420271.
A modified technique for catheterization of the pulmonary artery was developed. It involves the passage of a tapered, movable-core, J-tipped guide wire across the right ventricle into the pulmonary artery followed by the advancement of a straightened Grollman pigtail catheter. The technique was successful in 34 of 34 pulmonary artery catheterizations. The method avoids prolonged catheter manipulation within the right ventricle. In addition, since the catheter does not cross the tricuspid valve until the guide wire has been advanced, the occasional complication of the pigtail "hooking" on a tricuspid valve leaflet or chordae tendineae during catheter withdrawal and manipulation is prevented.
一种改良的肺动脉导管插入术被研发出来。它包括将一根锥形、可移动芯、J形头的导丝穿过右心室进入肺动脉,随后推进一根拉直的格罗曼猪尾导管。该技术在34例肺动脉导管插入术中全部成功。该方法避免了在右心室内长时间操作导管。此外,由于在导丝推进之前导管不会穿过三尖瓣,所以在导管回撤和操作过程中,猪尾导管偶尔会“钩住”三尖瓣叶或腱索的并发症得以避免。