Fielden E M, Sapora O, Loverock P S
Int J Radiat Biol Relat Stud Phys Chem Med. 1978 Jan;33(1):41-5. doi: 10.1080/09553007714551471.
Concentration versus radiosensitizing effect curves have been determined for four E. coli strains with two nitroaromatic sensitizers. The data are consistent with a simple competition kinetic model of sensitization, and K values for Ro 07-0582 are reported. An empirical relationship, DMF=alpha o.e.r., relating the dose-modifying factor produced by a given concentration of sensitizer to the oxygen-enhancement ratio of a bacterium was found to hold for all the mutants tested for values of alpha greater than 1/o.e.r. The limiting value of alpha at high concentrations of sensitizer was 0.75. Some implications of this relationship and the limiting value of alpha are discussed.