估算常见计算机断层扫描检查中儿科患者的诊断参考水平和可达到剂量:一项多中心研究。

ESTIMATION OF DIAGNOSTIC REFERENCE LEVELS AND ACHIEVABLE DOSES FOR PEDIATRIC PATIENTS IN COMMON COMPUTED TOMOGRAPHY EXAMINATIONS: A MULTI-CENTER STUDY.

机构信息

Department of Medical Physics, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd 8915173160, Iran.

Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.

出版信息

Radiat Prot Dosimetry. 2021 Aug 2;194(4):214-222. doi: 10.1093/rpd/ncab093.

Abstract

This study was conducted to determine first local diagnostic reference levels (DRLs) and achievable doses (ADs) for pediatric patients during the most common computed tomography (CT) procedures in Yazd province. The DRL was obtained based on volume CT dose index (CTDIvol) and dose length product (DLP) for four various age groups of children. Data were collected from the most commonly performed pediatric CT scans, including abdomen-pelvis, chest, brain and sinus examinations, at six high-loaded institutes. The patients' data (766 no.) in terms of CTDIvol and DLP were obtained from four age groups: ≤1-, 1-5-, 5-10- and 10-15-y-old. The 75th percentiles of CTDIvol and DLP were considered as DRL values and the 50th percentiles were described as ADs for those parameters. Consequently, the acquired DRLs were compared with other national and international published values. The DRLs in terms of CTDIvol for abdomen-pelvis, chest, brain and sinus examinations were 3, 8, 9 and 10 mGy; 4, 5, 5 and 5 mGy; 25, 28, 29 and 38 mGy; and 23, 24, 26 and 27 mGy for four different age groups of ≤1-, 1-5-, 5-10- and 10-15-y-old, respectively. The DRL values in terms of DLP were 75, 302, 321 and 342 mGy.cm; 109, 112, 135 and 170 mGy.cm, 352, 355, 360 and 481 mGy.cm; and 206, 211, 228 and 245 mGy.cm, respectively, for the mentioned age groups. In this study, the DRL and AD values in the brain examination were greater among the other studied regions. The DRL plays a critical role in the optimization of radiation doses delivered to patients and in improving their protection. This study provides the local DRLs and ADs for the most common pediatric CT scanning in Yazd province to create optimum situation for the clinical practice.

摘要

本研究旨在确定伊朗亚兹德省最常见的儿童计算机断层扫描(CT)检查中儿科患者的本地诊断参考水平(DRL)和可达到剂量(AD)。根据四个不同年龄组儿童的体层 CT 剂量指数(CTDIvol)和剂量长度乘积(DLP)获得 DRL。从六个高负荷机构中进行的最常见的儿科 CT 扫描中收集了数据,包括腹部-骨盆、胸部、大脑和鼻窦检查。从四个年龄组获得了 766 名患者的 CTDIvol 和 DLP 数据:≤1 岁、1-5 岁、5-10 岁和 10-15 岁。将 CTDIvol 和 DLP 的第 75 百分位数视为 DRL 值,并将这些参数的第 50 百分位数描述为 AD。因此,将获得的 DRL 与其他国家和国际发表的值进行了比较。在腹部-骨盆、胸部、大脑和鼻窦检查中,CTDIvol 的 DRL 分别为 3、8、9 和 10 mGy;4、5、5 和 5 mGy;25、28、29 和 38 mGy;23、24、26 和 27 mGy,分别为四个不同年龄组≤1 岁、1-5 岁、5-10 岁和 10-15 岁。以 DLP 表示的 DRL 值分别为 75、302、321 和 342 mGy.cm;109、112、135 和 170 mGy.cm;352、355、360 和 481 mGy.cm;206、211、228 和 245 mGy.cm,分别为所述年龄组。在本研究中,大脑检查的 DRL 和 AD 值在其他研究区域中更高。DRL 在优化向患者提供的辐射剂量和改善其保护方面发挥着关键作用。本研究为亚兹德省最常见的儿科 CT 扫描提供了本地 DRL 和 AD 值,为临床实践创造了最佳条件。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验