Suppr超能文献

宫颈癌腔内后装治疗中 tandem 和 ring 与 tandem 和 ovoids 应用的长期临床结果和剂量学比较。

Long-term clinical outcome and dosimetric comparison of tandem and ring versus tandem and ovoids intracavitary application in cervical cancer.

机构信息

Department of Radiation Oncolocy, Medical Faculty of Health Science University, Dr.Abdurrahmant Yurtaslan Oncology Research and Training Hospital, Ankara, Turkey.

出版信息

J BUON. 2021 May-Jun;26(3):698-706.

Abstract

PURPOSE

The two most common applicators used in the treatment of high dose rate (HDR) intracavitary brachytherapy (ICBT) are tandem and ovoid (TO) and tandem and ring (TR). We aimed to evaluate the relationship between these treatment plans with short and long-term clinical outcomes.

METHODS

This retrospective study included 50 patients who received a partial or complete response to external beam radiotherapy treatment (EBRT) and who were diagnosed with cervical cancer in our clinic between November 2015 and October 2019, including 25 TO patients and 25 TR patients. Left and right point A, high-risk clinical target volume (HR-CTV) EQD2, D0.1cc, 1cc, 2cc for the bladder, rectum, sigmoid, upper, middle, and lower vagina doses were recorded and compared according to the applicator type using the dose-volume histogram (DVH) parameter calculated from 200 computed tomography (CT) databases.

RESULTS

Right point A dose EQD2, HR-CTVD90,95,98, D2cc rectum EQD2, upper vagina V7Gy, 10Gy, middle and lower vagina 0,1, 1, 2cc, upper vagina 5-mm lateral point dose and upper, middle, lower vagina average doses were all found to be significantly lower for TR than for TO (p<0.005).

CONCLUSIONS

Although right point A dose EQD2, HR-CTVD90,95,98 values were higher in TO than in TR, the rectum and vaginal doses also seemed more advantageous in TR. GUS and GIS toxicities, local control, distant metastasis, treatment responses and survival rates were similar in both the applicators, although vaginal toxicity was observed more in TO. Studies with a higher number of patients are warranted in the future.

摘要

目的

在高剂量率(HDR)腔内近距离放射治疗(ICBT)中,最常用的两种施源器是 tandem 和 ovoid(TO)以及 tandem 和 ring(TR)。我们旨在评估这些治疗计划与短期和长期临床结果之间的关系。

方法

本回顾性研究纳入了 2015 年 11 月至 2019 年 10 月期间在我院接受外照射放疗(EBRT)治疗并部分或完全缓解的 50 例宫颈癌患者,包括 25 例 TO 患者和 25 例 TR 患者。根据施源器类型,记录左、右侧点 A、高风险临床靶区(HR-CTV)EQD2、D0.1cc、1cc、2cc 膀胱、直肠、乙状结肠、上、中、下阴道剂量,并通过 200 个 CT 数据库计算的剂量-体积直方图(DVH)参数进行比较。

结果

TR 组右侧点 A 剂量 EQD2、HR-CTV D90、95、98、直肠 D2cc EQD2、上阴道 V7Gy、10Gy、中、下阴道 0、1、1、2cc、上阴道 5mm 外侧点剂量以及上、中、下阴道平均剂量均显著低于 TO 组(p<0.005)。

结论

尽管 TO 组右侧点 A 剂量 EQD2、HR-CTV D90、95、98 值高于 TR 组,但直肠和阴道剂量在 TR 组似乎更有利。尽管在 TO 组中观察到更多的阴道毒性,但两种施源器的 GUS 和 GIS 毒性、局部控制、远处转移、治疗反应和生存率相似。未来需要进行更多患者的研究。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验