Abstract

Steady state glucose turnover was measured in 53 conscious, unrestrained neonatal piglets by two different methods using 3H-labelled glucose as the tracer. In the first, model-dependent method, the plasma tracer concentrations following a spike injection of tracer were fitted in various different ways and the turnover was calculated from the area under the fitted curve extrapolated to infinity. Both exponential curves and negative power functions of time were fitted by non-linear least squares. In the second, model-independent method, tracer was infused continuously and turnover calculated from its equilibrium concentration. Conditions during 34 of the 53 experiments failed various tests of the steady state and the data were therefore discarded. In the remaining 19, glucose turnover measured by the different methods agreed fairly well. Although there was little difference between the results obtained by a two-exponential curve fit, by those obtained when the fast component was ignored, by a single exponential curve fit, and by the results from fitting a negative power function of time, the conventional two-exponential curve is to be preferred. There was a suggestion that at high turnover rates, the injection result underestimated the infusion result, assuming the latter to represent the reference method. This might have been due to extrapolation errors in the injection technique, either in the first few minutes following injection, or in the interval after the last sample. However, the notional volumes of distribution of the tracer suggest that the terminal phase of tracer elimination is in fact slightly faster than that predicted on the basis of samples taken during the first 120 min post-injection.

摘要

采用两种不同方法,以3H标记葡萄糖作为示踪剂,对53头清醒、未受约束的新生仔猪的稳态葡萄糖周转率进行了测定。在第一种依赖模型的方法中,对示踪剂脉冲注射后的血浆示踪剂浓度采用多种不同方式进行拟合,并根据拟合曲线外推至无穷大的曲线下面积计算周转率。时间的指数曲线和负幂函数均采用非线性最小二乘法进行拟合。在第二种不依赖模型的方法中,持续输注示踪剂,并根据其平衡浓度计算周转率。53项实验中有34项实验期间的条件未通过稳态的各项测试,因此这些数据被舍弃。在其余19项实验中,采用不同方法测得的葡萄糖周转率相当吻合。尽管通过双指数曲线拟合得到的结果、忽略快速成分时得到的结果、单指数曲线拟合得到的结果以及时间负幂函数拟合得到的结果之间差异不大,但传统的双指数曲线更为可取。有人提出,在高周转率时,假设输注结果代表参考方法,注射法结果会低估输注法结果。这可能是由于注射技术中的外推误差,要么是注射后的头几分钟内,要么是最后一个样本后的间隔期。然而,示踪剂的理论分布体积表明,示踪剂消除的终末相实际上比注射后最初120分钟内采集样本所预测的要略快一些。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验