Daneshnia Kousar, Rasouli Mehdi
Department of Clinical Biochemistry and Immunogenetic Research Center, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Mazandaran, Iran.
Clin Exp Hepatol. 2021 Jun;7(2):165-171. doi: 10.5114/ceh.2021.106527. Epub 2021 May 28.
The secretion rate of triglyceride from rat liver is assayed by the measurement of triglyceride accumulation in plasma when its clearance is inhibited. The aim of the study was to measure and compare the secretion rate of triglyceride from rat liver by two methods of fixed-time and continuous assays.
A single dose of 200 mg of poloxamer-407 (P-407) was injected i.p. into starved male rats. The secretion rate of triglyceride was measured by fixed-time and continuous assays.
The time course for the changes of serum triglyceride following injection of P-407 showed three distinct phases: a lag period of about 30 minutes, a linear increase in serum triglyceride that lasted more than 4 hours, and a slight decline of triglyceride accumulation that lasted about 24 hours. The mean rate of triglyceride secretion was 234.1 ±9.6 mg/dl/h during the linear phase. The linear phase was divided into five time protocols of 240, 180, 120, 60, and 30 minutes and the secretion rate was measured at three points of time in each protocol. The mean rate of triglyceride secretion was 3.91 ±0.15, 3.83 ±0.16, 3.76 ±0.29, 3.57 ±0.43 and 3.13 ±0.34 mg/dl/min in these protocols respectively. In the kinetic assay, the change in the absorbance per three successive five minutes (ΔA/Δt) was measured and the secretion rate was calculated as 3.82 ±0.11 mg/dl/min.
The rate of triglyceride secretion can be measured by both fixed-time and kinetic assays and was about 3.82 ±0.11 mg/dl/min. The results of the two methods are more corresponded as the mean and instantaneous velocity respectively.
当大鼠肝脏甘油三酯清除受到抑制时,通过测量血浆中甘油三酯的蓄积来测定大鼠肝脏甘油三酯的分泌率。本研究的目的是通过定时测定法和连续测定法这两种方法来测量和比较大鼠肝脏甘油三酯的分泌率。
向饥饿的雄性大鼠腹腔注射单剂量200mg泊洛沙姆-407(P-407)。通过定时测定法和连续测定法测量甘油三酯的分泌率。
注射P-407后血清甘油三酯变化的时间进程显示出三个不同阶段:约30分钟的延迟期、持续超过4小时的血清甘油三酯线性增加期以及持续约24小时的甘油三酯蓄积略有下降期。线性期甘油三酯分泌的平均速率为234.1±9.6mg/dl/h。线性期分为240、180、120、60和30分钟的五个时间方案,每个方案在三个时间点测量分泌率。在这些方案中,甘油三酯分泌的平均速率分别为3.91±0.15、3.83±0.16、3.76±0.29、3.57±0.43和3.13±0.34mg/dl/min。在动力学测定中,测量每连续五分钟的吸光度变化(ΔA/Δt),计算分泌率为3.82±0.11mg/dl/min。
甘油三酯分泌率可以通过定时测定法和动力学测定法进行测量,约为3.82±0.11mg/dl/min。这两种方法的结果分别更符合平均值和瞬时速度。