使用估计而非测量的耗氧量,通过改良的菲克法测定心输出量。

Determination of cardiac output with a modified Fick method using estimated instead of measured oxygen consumption.

作者信息

Dale J, Jespersen L

机构信息

Medical Department, Vest-Agder Sentralsykehus, Kristiansand, Norway.

出版信息

Scand J Clin Lab Invest. 1987 Dec;47(8):759-63.

PMID:3432997
Abstract

Cardiac output (CO) was determined with a modification of the Fick method using estimated, instead of measured, oxygen consumption values. This avoids several possible sources of error in connection with air sampling and oxygen content analysis, thus a relaxed, steady state is obtained more easily. Using the thermodilution technique a good correlation with CO values was found (r = 0.92, p less than 0.001). We conclude that the modified Fick method is simple, accurate and offers reproducible CO estimates in the majority of patients.

摘要

心输出量(CO)采用改良的菲克法测定,该方法使用估算的而非测量的耗氧量值。这避免了与空气采样和氧含量分析相关的几个可能的误差来源,从而更容易获得轻松的稳态。使用热稀释技术发现与CO值具有良好的相关性(r = 0.92,p < 0.001)。我们得出结论,改良的菲克法简单、准确,并且在大多数患者中能够提供可重复的心输出量估计值。