Suppr超能文献

保留肌肉的肌腱移植与去除肌肉附着的肌腱移植具有相似的生物力学特性:猪模型的生物力学评估

Tendon grafts with preserved muscle demonstrate similar biomechanical properties to tendon grafts stripped of muscular attachments: a biomechanical evaluation in a porcine model.

作者信息

Funchal Luis Fernando Zukanovich, Astur Diego Costa, Pizzolatti André Luiz Almeida, Grimaldi Arthur Paiva, Jimenez Andrew Esteban, Moré Ari Digiácomo Ocampo, de Mello Roesler Carlos Rodrigo, Cohen Moises

机构信息

Biomechanical Laboratory From Universidade Federal de Santa Catarina, Hospital Baia Sul, Florianópolis, Brazil.

Universidade Federal de São Paulo, Hospital Samaritano and Instituto Astur, Av Pacaembu 1024, São Paulo, SP, 01234-000, Brazil.

出版信息

J Exp Orthop. 2021 Aug 2;8(1):57. doi: 10.1186/s40634-021-00375-6.

Abstract

PURPOSE

(1) To evaluate the biomechanical properties of a porcine flexor digitorum superficialis tendon graft with preserved muscle fibers and (2) to compare these results with the biomechanical properties of a porcine tendon graft after removal of associated muscle.

METHODS

Eighty-two porcine forelegs were dissected and the flexor digitorum superficialis muscle tendons were harvested. The study comprised of two groups: Group 1 (G1), harvested tendon with preserved muscle tissue; and Group 2 (G2), harvested contralateral tendon with removal of all muscle tissue. Tests in both groups were conducted using an electro-mechanical material testing machine (Instron, model 23-5S, Instron Corp., Canton, MA, USA) with a 500 N force transducer. Yield load, stiffness, and maximum load were evaluated and compared between groups.

RESULTS

The behavior of the autografts during the tests followed the same stretching, deformation, and failure patterns as those observed in human autografts subjected to axial strain. There were no significant differences in the comparison between groups for ultimate load to failure (p = 0.105), stiffness (p = 0.097), and energy (p = 0.761).

CONCLUSION

In this porcine model biomechanical study, using autograft tendon with preserved muscle showed no statistically significant differences for yield load, stiffness, or maximum load compared to autograft tendon without preserved muscle. The preservation of muscle on the autograft tendon did not compromise the mechanical properties of the autograft.

LEVEL OF EVIDENCE

Level III Controlled laboratory study.

摘要

目的

(1)评估保留肌纤维的猪指浅屈肌腱移植物的生物力学特性;(2)将这些结果与去除相关肌肉后的猪肌腱移植物的生物力学特性进行比较。

方法

解剖82只猪的前肢,获取指浅屈肌腱。该研究分为两组:第1组(G1),保留肌肉组织的收获肌腱;第2组(G2),去除所有肌肉组织的对侧收获肌腱。两组均使用配有500 N力传感器的机电材料试验机(Instron,型号23 - 5S,Instron公司,美国马萨诸塞州坎顿)进行测试。评估并比较两组之间的屈服载荷、刚度和最大载荷。

结果

自体移植物在测试过程中的行为与在承受轴向应变的人体自体移植物中观察到的拉伸、变形和破坏模式相同。两组之间在破坏极限载荷(p = 0.105)、刚度(p = 0.097)和能量(p = 0.761)的比较上无显著差异。

结论

在该猪模型生物力学研究中,与未保留肌肉的自体移植物肌腱相比,使用保留肌肉的自体移植物肌腱在屈服载荷、刚度或最大载荷方面无统计学显著差异。自体移植物肌腱上肌肉的保留并未损害自体移植物的力学性能。

证据水平

III级对照实验室研究。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1149/8329107/44f2a759fc6a/40634_2021_375_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验