En una cesárea se puede emplear analgesia epidural con bupivacaína 0.125% and lidocaína 1.5% ó bupivacaína 0.25% and lidocaína 1.0%. Una concentración mayor de bupivacaína alcanza mayor analgesia con más eventos adversos.
evaluar la analgesia y seguridad de bupivacaína 0.125% and lidocaína 1.5% ó bupivacaína 0.25% and lidocaína 1.0%.
MATERIALES Y MÉTODOS: Cohorte prospectivo estratificado según ambas concentraciones de bupivacaína.
Se recuperó cien gestantes a término (cincuenta por cohorte). A los 20 y 30 minutos tras la administración epidural hubo más casos con mayor bloqueo motor en quienes se empleó bupivacaína 0.125% and lidocaína 1.5% (p = 0.0229 y p = 0.0006, respectivamente). No hubo diferencia significativa respecto al bloqueo sensitivo. Bupivacaína 0.25% and lidocaína 1.5% mostró una tencencia a la hipotensión (p < 0.001) y a la bradicardia (p = 0.4100). De la cohorte de bupivacaína 0.125% and lidocaína 1.5%, 25 casos (50%) presentaron cuando menos un evento adverso, en contraste con 44/50 (88%) de la cohorte de bupivacaína 0.25% and lidocaína 1.0% (p < 0.001).
CONCLUSIÓN: En la analgesia epidural durante cesárea, bupivacaína 0.125% and lidocaína 1.5% está asociado con un efecto analgésico similar a bupivacaína 0.25% and lidocaína 1.0%. Sin embargo, mayores concentraciones están significativamente relacionadas con mayor tasa de eventos adversos (especialmente hipotensión).
In a cesarean section, epidural analgesia with 0.125% bupivacaine and 1.5% lidocaine or 0.25% bupivacaine with 1.0% lidocaine concentrations can be used. A higher concentration of bupivacaine reaches better analgesia but with a higher rate of drug-related adverse events.
The aim of the study was to assess analgesia and safety of 0.125% bupivacaine and 1.5% lidocaine or 0.25% bupivacaine with 1.0% lidocaine during cesarean.
Prospective cohort stratified following both bupivacaine concentrations.
One hundred women with full-term pregnancies were selected (fifty per cohort). At 20 and 30 min after epidural administration, there was a higher proportion of motor blockade cases from the 0.125% bupivacaine and 1.5% lidocaine cohort (p = 0.0229 and p = 0.0006, respectively). There was no significant difference among sensitive blockage. A 0.25% bupivacaine and 1.0% lidocaine concentration showed a tendency to hypotension (p < 0.001) and bradycardia (p = 0.4100). From 0.125% bupivacaine and 1.5% lidocaine cohort, 25 cases (50%) presented at least one adverse event; in contrast with 44/50 (88%) from 0.25% bupivacaine and 1.0% lidocaine cohort (p < 0.001).
In epidural analgesia during cesarean, using 0.125% bupivacaine and 1.5% lidocaine presented similar analgesia than 0.25% bupivacaine and 1.0% lidocaine. However, a higher bupivacaine concentration is significantly related to more frequent drug-related adverse events (especially hypotension).
在剖宫产术中,可以使用 0.125%布比卡因和 1.5%利多卡因或 0.25%布比卡因和 1.0%利多卡因浓度的硬膜外镇痛。布比卡因浓度较高可达到更好的镇痛效果,但与药物相关的不良事件发生率较高。
评估 0.125%布比卡因和 1.5%利多卡因或 0.25%布比卡因与 1.0%利多卡因在剖宫产术中的镇痛和安全性。
按照两种布比卡因浓度进行前瞻性分层的队列研究。
共纳入 100 例足月妊娠产妇(每组 50 例)。在硬膜外给药后 20 和 30 分钟,0.125%布比卡因和 1.5%利多卡因组的运动阻滞病例比例更高(p=0.0229 和 p=0.0006)。感觉阻滞无显著差异。0.25%布比卡因和 1.0%利多卡因浓度组表现出低血压的趋势(p<0.001)和心动过缓(p=0.4100)。0.125%布比卡因和 1.5%利多卡因组有 25 例(50%)至少出现 1 种不良事件,而 0.25%布比卡因和 1.0%利多卡因组有 44/50(88%)例(p<0.001)。
在剖宫产术中,使用 0.125%布比卡因和 1.5%利多卡因的镇痛效果与 0.25%布比卡因和 1.0%利多卡因相似。然而,较高的布比卡因浓度与更频繁的药物相关不良事件显著相关(特别是低血压)。