Sapora Joseph A, Hafez Ahmed, Monnet Eric
Department of Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, Colorado, USA.
Faculty of Veterinary Medicine, Department of Surgery, Anesthesiology, and Radiology, Beni-Suef University, Beni-Suef, Egypt.
Vet Surg. 2021 Oct;50(7):1495-1501. doi: 10.1111/vsu.13705. Epub 2021 Aug 6.
To compare leakage pressures of colonic anastomoses performed with circular staplers to conventional hand-sewn techniques in dogs.
Ex-vivo study.
Colon from 11 canine cadavers.
Thirty-two colonic anastomoses were performed. Four segments from each colon were randomly assigned to one of four techniques: hand-sewn colonic anastomoses performed with 4-0 glycomer 631 (G) and 4-0 barbed glycomer 631 (BG), and circular stapled colonic anastomoses using 4.8 mm End-to-End Anastomosis (EEA C4.8mm) and 3.5 mm End-to-End Anastomosis (EEA C3.5mm), 21 mm diameter circular staples in cadaveric canine colon. Leakage pressure was defined as the pressure at which dye-containing solution was first observed to leak from the anastomosis site.
Leakage pressures were 49.5 mmHg (range:16-72) in group G, 45.5 mmHg (range:19-80) in group BG, 5.3 mmHg (range:0-31) in group C3.5mm, and 29.5 mmHg (range:23-50.3) in group C4.8mm. Anastomoses leaked at lower pressures when stapled rather than hand-sewn (C4.8mm-G p = .0313, C4.8mm-BG p = .0131, C3.5mm-G p = .0469, C3.5mm-BG p = .0313). Two of the C3.5mm constructs leaked immediately after saline infusion with 4/6 leaking at <5.3 mmHg.
End-to-end colonic anastomoses closed with circular stapler leaked at lower pressures than hand-sutured anastomoses. Use of the EEA stapler with a staple height of 3.5 mm did not result in safe colonic anastomoses.
These results provide evidence to support hand-suturing colonic anatomoses with G and BG in dogs. The 4.8 mm staples may be considered in anatomical locations difficult to reach.
比较犬类中使用圆形吻合器进行结肠吻合与传统手工缝合技术的漏出压力。
体外研究。
11只犬类尸体的结肠。
进行了32例结肠吻合。每段结肠的四个部分被随机分配到四种技术之一:用4-0聚乙醇酸631(G)和4-0倒刺聚乙醇酸631(BG)进行手工缝合结肠吻合,以及使用4.8毫米端端吻合器(EEA C4.8mm)和3.5毫米端端吻合器(EEA C3.5mm)、直径21毫米的圆形吻合钉在犬类尸体结肠中进行圆形吻合器结肠吻合。漏出压力定义为首次观察到含染料溶液从吻合部位漏出时的压力。
G组漏出压力为49.5毫米汞柱(范围:16 - 72),BG组为45.5毫米汞柱(范围:19 - 80),C3.5mm组为5.3毫米汞柱(范围:0 - 31),C4.8mm组为29.5毫米汞柱(范围:23 - 50.3)。吻合器吻合时吻合口漏出压力低于手工缝合(C4.8mm - G p = 0.0313,C4.8mm - BG p = 0.0131,C3.5mm - G p = 0.0469,C3.5mm - BG p = 0.0313)。C3.5mm组中有2例在注入生理盐水后立即漏出,4/6例在<5.3毫米汞柱时漏出。
用圆形吻合器进行的端端结肠吻合漏出压力低于手工缝合的吻合口。使用钉高3.5毫米的EEA吻合器未实现安全的结肠吻合。
这些结果为支持在犬类中用G和BG手工缝合结肠吻合提供了证据。在难以到达的解剖位置可考虑使用4.8毫米的吻合钉。