手持式与座式激光散斑对比灌注成像在银屑病皮损中的应用。

Handheld versus mounted laser speckle contrast perfusion imaging demonstrated in psoriasis lesions.

机构信息

Biomedical Photonic Imaging, Technical Medical Centre, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500 AE, Enschede, The Netherlands.

Department of Dermatology, Radboud University Medical Center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands.

出版信息

Sci Rep. 2021 Aug 17;11(1):16646. doi: 10.1038/s41598-021-96218-6.

Abstract

Enabling handheld perfusion imaging would drastically improve the feasibility of perfusion imaging in clinical practice. Therefore, we examine the performance of handheld laser speckle contrast imaging (LSCI) measurements compared to mounted measurements, demonstrated in psoriatic skin. A pipeline is introduced to process, analyze and compare data of 11 measurement pairs (mounted-handheld LSCI modes) operated on 5 patients and various skin locations. The on-surface speeds (i.e. speed of light beam movements on the surface) are quantified employing mean separation (MS) segmentation and enhanced correlation coefficient maximization (ECC). The average on-surface speeds are found to be 8.5 times greater in handheld mode compared to mounted mode. Frame alignment sharpens temporally averaged perfusion maps, especially in the handheld case. The results show that after proper post-processing, the handheld measurements are in agreement with the corresponding mounted measurements on a visual basis. The absolute movement-induced difference between mounted-handheld pairs after the background correction is [Formula: see text] (mean ± std, [Formula: see text]), with an absolute median difference of [Formula: see text]. Realization of handheld LSCI facilitates measurements on a wide range of skin areas bringing more convenience for both patients and medical staff.

摘要

实现手持式灌注成像将极大地提高临床实践中灌注成像的可行性。因此,我们研究了手持式激光散斑对比成像(LSCI)测量与安装式测量的性能比较,该研究在银屑病皮肤中进行。引入了一个处理、分析和比较 5 名患者和不同皮肤部位的 11 对测量(安装式-手持式 LSCI 模式)数据的管道。采用平均分离(MS)分割和增强相关系数最大化(ECC)对表面速度(即光束在表面上的移动速度)进行量化。结果表明,与安装式模式相比,手持式模式下的表面速度平均提高了 8.5 倍。帧对准可锐化时间平均灌注图,尤其是在手持式情况下。结果表明,经过适当的后处理,手持式测量与相应的安装式测量在视觉上是一致的。背景校正后安装式-手持式对的绝对运动引起的差异为 [Formula: see text](平均值 ± 标准差,[Formula: see text]),绝对中位数差异为 [Formula: see text]。手持式 LSCI 的实现方便了对广泛皮肤区域的测量,为患者和医务人员提供了更多便利。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c076/8371022/935f4d44c836/41598_2021_96218_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验