31A2型股骨转子间髋部骨折采用短型和长型股骨近端髓内钉固定时透视时间的比较。

Comparison of fluoroscopy time in short and long cephalomedullary nailing for 31A2 intertrochanteric hip fractures.

作者信息

Vishwanathan Karthik, Akbari Keyur, Patel Amit

出版信息

Acta Orthop Belg. 2021 Jun;87(2):305-311.

Abstract

There is no study that has compared the radiation exposure during short (Short PFN) and long proximal femoral nailing (Long PFN) for 31A2 intertrochanteric hip fractures. The objective of the present study was to compare the radiation exposure time in short and long proximal femoral nail during the treatment of 31A2 intertrochanteric hip fractures. This prospective cohort study was carried out in a University teaching hospital. Sixty one consecutive patients with 31A2 intertrochanteric femur fracture treated with proximal femoral nail were included in the study. The distal locking in the short PFN was performed using the locking zig and distal locking in the long PFN was performed using the free hand perfect circle technique. The same mobile image intensifier (Multimobil 5E, Siemens, Erlangen, Germany) was used in the entire study. The outcome measure was the fluoroscopy exposure time (seconds) which was measured directly from the image intensifier. Thirty patients underwent fixation with short PFN and 31 patients underwent fixation using long PFN. The mean fluoroscopy exposure time in short PFN cohort was 189.5 seconds ± 26 (range : 150-250 seconds) and the mean fluoroscopy exposure time in long PFN cohort was 283.4 seconds ± 43.8 (range : 200-400 seconds). The mean fluoroscopy exposure time was 93.9 seconds shorter in the short PFN cohort and this difference was statistically significant (p & 0.0001 ; 95% CI : 75.4 to 112.3). The radiation exposure to the operating team is significantly less during treatment with short PFN in 31A2 intertrochanteric fractures.

摘要

尚无研究比较 31A2 型股骨转子间髋部骨折采用短型股骨近端髓内钉(Short PFN)和长型股骨近端髓内钉(Long PFN)治疗时的辐射暴露情况。本研究的目的是比较 31A2 型股骨转子间髋部骨折治疗过程中短型和长型股骨近端髓内钉的辐射暴露时间。这项前瞻性队列研究在一家大学教学医院进行。连续 61 例采用股骨近端髓内钉治疗 31A2 型股骨转子间骨折的患者纳入本研究。Short PFN 的远端锁定采用锁定之字形技术,Long PFN 的远端锁定采用徒手完美圆圈技术。整个研究使用同一台移动影像增强器(Multimobil 5E,西门子,德国埃尔朗根)。观察指标为透视暴露时间(秒),直接从影像增强器测量。30 例患者采用 Short PFN 固定,31 例患者采用 Long PFN 固定。Short PFN 队列的平均透视暴露时间为 189.5 秒±26(范围:150 - 250 秒);Long PFN 队列的平均透视暴露时间为 283.4 秒±43.8(范围:200 - 400 秒)。Short PFN 队列的平均透视暴露时间短 93.9 秒,且这一差异具有统计学意义(p<0.0001;95%CI:75.4 至 112.3)。在 31A2 型股骨转子间骨折治疗中,采用 Short PFN 时手术团队所受的辐射暴露明显更少。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验