Abstract

OBJECTIVE

Magnification error is always present in radiography and calibration is necessary, if high accuracy is required in pre-surgical planning. The goal of this study was to verify the use of self-made markers and calibration techniques and to establish guidelines for magnification correction.

STUDY DESIGN

We evaluated and compared spherical and linear markers of different sizes with focus on practicability, accuracy and precision. Markers were placed on foam pads or attached to flexible arms.

RESULTS

Vertical marker deviation of 1 cm from the anatomical reference point corresponded to ∼1% of magnification error in our setting. Marker placement along the horizontal plane showed no significant magnification in the periphery of the radiograph. All markers showed good accuracy and the commercial spherical marker with a flexible segment arm had the best results regarding practicability.

CONCLUSION

Our study suggests that marker type is not solely responsible for usability and accuracy but also the type of fixation. In the absence of a calibration marker, calculation of the magnification factor using a measurement tape during radiography is equally reliable. Use of a fixed averaged calculated calibration factor showed poor agreement compared with the marker calibration, probably due to variability in size of the animals. In conclusion, if precision matters, use of a calibration marker, which could be purchased or self-made, is advised.

摘要

目的

如果需要在术前规划中获得高精度,那么在放射摄影中始终存在放大误差,并且需要进行校准。本研究的目的是验证自制标记物和校准技术的使用,并为放大校正制定指南。

研究设计

我们评估和比较了不同尺寸的球形和线性标记物,重点是实用性、准确性和精密度。标记物放置在泡沫垫上或固定在柔性臂上。

结果

在我们的设置中,垂直标记物从解剖参考点偏离 1cm 对应于约 1%的放大误差。沿着水平平面放置标记物在射线照片的外围没有明显的放大。所有标记物均具有良好的准确性,并且具有柔性段臂的商用球形标记物在实用性方面具有最佳效果。

结论

我们的研究表明,标记物类型不仅决定了可用性和准确性,还决定了固定类型。在没有校准标记物的情况下,在拍摄射线照片时使用卷尺计算放大系数同样可靠。与标记物校准相比,使用固定的平均计算校准系数的一致性较差,这可能是由于动物的大小不同所致。总之,如果精度很重要,则建议使用校准标记物,该标记物可以是购买的也可以是自制的。