Suppr超能文献

超声评估糖尿病患者足底皮肤和脂肪垫的可靠性。

Reliability of ultrasound in evaluating the plantar skin and fat pad of the foot in the setting of diabetes.

机构信息

Allied Health and Human Performance, University of South Australia, Adelaide, South Australia, Australia.

Department of Rural Health, University of South Australia, Whyalla Norrie, South Australia, Australia.

出版信息

PLoS One. 2021 Sep 23;16(9):e0257790. doi: 10.1371/journal.pone.0257790. eCollection 2021.

Abstract

Ultrasound can be used to assess injury and structural changes to the soft-tissue structure of the foot. It may be useful to assess the feet of people with diabetes who are at increased risk of plantar soft-tissue pathological changes. The aim of this study was to determine if ultrasound measurements of plantar soft-tissue thickness and assessments of tissue acoustic characteristics are reliable in people with and without diabetes mellitus. A repeated measures design was used to determine intra-observer reliability for ultrasound measurements of plantar skin and fat pad thickness and intra- and inter-observer reliability of plantar skin and fat pad tissue characterisation assessments made at foot sites which are at risk of tissue injury in people with diabetes. Thickness measurements and tissue characterisation assessments were obtained at the heel and forefoot in both the unloaded and compressed states and included discrete layers of the plantar tissues: skin, microchamber, horizontal fibrous band, macrochamber and total soft-tissue depth. At each site, relative intra-observer reliability was achieved for the measurement of at least one plantar tissue layer. The total soft-tissue thickness measured in the unloaded state (ICC 0.925-0.976) demonstrated intra-observer reliability and is the most sensitive for detecting small change on repeated measures. Intra-observer agreement was demonstrated for tissue characteristic assessments of the skin at the heel (k = 0.70), fat pad at the lateral sesamoid region (k = 0.70) and both skin and fat pad at the second (k = 0.80, k = 0.70 respectively) and third metatarsal heads (k = 0.90, k = 0.79 respectively). However, acceptable inter-observer agreement was not demonstrated for any tissue characteristic assessment, therefore the use of multiple observers should be avoided when making these assessments.

摘要

超声可用于评估足部软组织的损伤和结构变化。它可能有助于评估有发生足底软组织病理性改变风险的糖尿病患者的足部。本研究旨在确定超声测量足底软组织厚度和组织声学特性评估在糖尿病患者和非糖尿病患者中是否具有可靠性。采用重复测量设计来确定在糖尿病患者足部有组织损伤风险的部位进行的足底皮肤和脂肪垫厚度的超声测量的观察者内可靠性,以及足底皮肤和脂肪垫组织特征评估的观察者内和观察者间可靠性。在未负重和压缩状态下,在足跟和前足处获得厚度测量值和组织特征评估值,包括足底组织的离散层:皮肤、微室、水平纤维带、大室和总软组织深度。在每个部位,至少有一个足底组织层的测量值均达到了相对观察者内可靠性。未负重状态下测量的总软组织厚度(ICC 0.925-0.976)具有观察者内可靠性,是检测重复测量中微小变化最敏感的指标。在足跟处皮肤(k = 0.70)、外侧籽骨区域脂肪垫(k = 0.70)以及第二和第三跖骨头处皮肤和脂肪垫(k = 0.80,k = 0.70;k = 0.90,k = 0.79)的组织特征评估中,观察到了观察者内一致性。然而,对于任何组织特征评估,均未观察到可接受的观察者间一致性,因此在进行这些评估时应避免使用多个观察者。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8287/8459958/d60a93d8c6ce/pone.0257790.g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验