University of Potsdam, University Outpatient Clinic, Sports Medicine and Sports Orthopaedics, Potsdam, Germany.
Br J Radiol. 2021 Nov 1;94(1127):20210141. doi: 10.1259/bjr.20210141. Epub 2021 Sep 24.
To assess the reliability of measurements of paraspinal muscle transverse relaxation times (T2 times) between two observers and within one observer on different time points.
14 participants (9f/5m, 33 ± 5 years, 176 ± 10 cm, 73 ± 12 kg) underwent 2 consecutive MRI scans (M1,M2) on the same day, followed by 1 MRI scan 13-14 days later (M3) in a mobile 1.5 Tesla MRI. T2 times were calculated in weighted turbo spin-echo-sequences at the spinal level of the third lumbar vertebrae (11 slices, 2 mm slice thickness, 1 mm interslice gap, echo times: 20, 40, 60, 80, 100 ms) for M. erector spinae (ES) and M. multifidius (MF). The following reliability parameter were calculated for the agreement of T2 times between two different investigators (OBS1 & OBS2) on the same MRI (inter-rater reliability, IR) and by one investigator between different MRI of the same participant (intersession variability, IS): Test-Retest Variability (TRV, Differences/Mean100); Coefficient of Variation (CV, Standard deviation/Mean100); Bland-Altman Analysis (systematic bias = Mean of the Differences; Upper/Lower Limits of Agreement = Bias+/-1.96*SD); Intraclass Correlation Coefficient 3.1 (ICC) with absolute agreement, as well as its 95% confidence interval.
Mean TRV for IR was 2.6% for ES and 4.2% for MF. Mean TRV for IS was 3.5% (ES) and 5.1% (MF). Mean CV for IR was 1.9 (ES) and 3.0 (MF). Mean CV for IS was 2.5% (ES) and 3.6% (MF). A systematic bias of 1.3 ms (ES) and 2.1 ms (MF) were detected for IR and a systematic bias of 0.4 ms (ES) and 0.07 ms (MF) for IS. ICC for IR was 0.94 (ES) and 0.87 (MF). ICC for IS was 0.88 (ES) and 0.82 (MF).
Reliable assessment of paraspinal muscle T2 time justifies its use for scientific purposes. The applied technique could be recommended to use for future studies that aim to assess changes of T2 times, after an intense bout of eccentric exercises.
评估两名观察者之间以及一名观察者在不同时间点测量竖脊肌横向弛豫时间(T2 时间)的可靠性。
14 名参与者(9 名女性/5 名男性,33±5 岁,176±10cm,73±12kg)在同一天进行了 2 次连续的 MRI 扫描(M1、M2),然后在 1.5T 移动 MRI 上进行了 1 次 13-14 天后的 MRI 扫描(M3)。在第 3 腰椎水平的加权涡轮自旋回波序列中计算 T2 时间(11 个切片,2mm 切片厚度,1mm 切片间隔,回波时间:20、40、60、80、100ms),用于测量竖脊肌(ES)和多裂肌(MF)的 T2 时间。计算了两名不同观察者(OBS1 和 OBS2)在同一 MRI 上的 T2 时间之间的以下可靠性参数(同测者间可靠性,IR)和同一名参与者不同 MRI 之间的 T2 时间(间测变异,IS):测试-重测变异(TRV,差异/平均值100);变异系数(CV,标准差/平均值100);Bland-Altman 分析(系统偏差=差异的平均值;上下限=偏差+/-1.96*SD);3.1 类内相关系数(ICC),具有绝对一致性,以及其 95%置信区间。
IR 的平均 TRV 为 ES 的 2.6%和 MF 的 4.2%。IS 的平均 TRV 为 ES 的 3.5%和 MF 的 5.1%。IR 的平均 CV 为 ES 的 1.9%和 MF 的 3.0%。IS 的平均 CV 为 ES 的 2.5%和 MF 的 3.6%。IR 检测到 1.3ms(ES)和 2.1ms(MF)的系统偏差,IS 检测到 0.4ms(ES)和 0.07ms(MF)的系统偏差。IR 的 ICC 为 0.94(ES)和 0.87(MF)。IS 的 ICC 为 0.88(ES)和 0.82(MF)。
可靠评估竖脊肌 T2 时间可证明其在科学研究中的应用合理。所应用的技术可推荐用于未来研究,旨在评估剧烈的离心运动后 T2 时间的变化。