Suppr超能文献

固定正畸治疗中两种不同初始弓丝用于牙齿排齐的比较——一项随机临床试验

Comparison of two different initial archwires for tooth alignment during fixed orthodontic treatment-A randomized clinical trial.

作者信息

Jain Shubhangi, Sharma Payal, Shetty Divya

机构信息

Department of Orthodontics and Dentofacial Orthopedics, I.T.S-CDSR, Muradnagar, Ghaziabad, Uttar Pradesh, India.

出版信息

J Orthod Sci. 2021 Aug 4;10:13. doi: 10.4103/jos.JOS_17_20. eCollection 2021.

Abstract

OBJECTIVES

The aim of the study was to clinically evaluate and compare 0.016-inch superelastic nickel-titanium (NiTi) and 0.016-inch heat-activated nickel-titanium (NiTi) archwires in terms of alignment efficiency, root resorption, and pain intensity.

METHOD

A total of 20 patients requiring fixed orthodontic treatment, having Little's irregularity index of 5-8, and requiring first premolar extractions were recruited. They were randomly allocated to receive two different archwires (0.016-inch superelastic NiTi or 0.016-inch thermoelastic NiTi). Good-quality impressions were taken of the lower arch before archwire placement (T0) and at every month after that till the alignment was complete. The rate of tooth alignment was measured on casts by determining Little's irregularity index. The pain experienced by the patient was assessed 24 hours and 1 week after the placement of the archwire on a visual analogue scale. Cone beam computed tomographic radiographs of lower anterior teeth were taken before and after alignment to assess root resorption. Data obtained were subjected to statistical analysis using the SPSS software (version 20.0). The level of significance was kept at 5%.

RESULTS

The repeated measures ANOVA indicated that there was no significant difference in the aligning efficiency of superelastic and heat-activated NiTi wires. (p = 0.45). The Mann Whitney U test showed that superelastic NiTi wires had statistically significant higher VAS scores than heat-activated NiTi at 24 hours and 1-week interval (p < 0.05). Student's t-test indicated greater root resorption with superelastic NiTi but the difference was not statistically significant.

CONCLUSION

Both the wires showed similar aligning efficiency and resulting root resorption. Superelastic NiTi was observed to produce more pain compared to heat-activated NiTi in the aligning phase.

摘要

目的

本研究旨在从排齐效率、牙根吸收和疼痛强度方面对0.016英寸超弹性镍钛(NiTi)弓丝和0.016英寸热激活镍钛(NiTi)弓丝进行临床评估和比较。

方法

共招募20例需要固定正畸治疗、Little不规则指数为5 - 8且需要拔除第一前磨牙的患者。他们被随机分配接受两种不同的弓丝(0.016英寸超弹性NiTi或0.016英寸热弹性NiTi)。在弓丝放置前(T0)以及此后每月直至排齐完成时,对下颌牙弓进行高质量印模制取。通过测定Little不规则指数在模型上测量牙齿排齐率。在弓丝放置后24小时和1周,采用视觉模拟量表评估患者经历的疼痛。在排齐前后拍摄下颌前牙的锥形束计算机断层扫描X线片以评估牙根吸收情况。使用SPSS软件(版本20.0)对获得的数据进行统计分析。显著性水平设定为5%。

结果

重复测量方差分析表明,超弹性和热激活NiTi弓丝在排齐效率方面无显著差异(p = 0.45)。Mann Whitney U检验显示,在24小时和1周时,超弹性NiTi弓丝的视觉模拟量表评分在统计学上显著高于热激活NiTi弓丝(p < 0.05)。Student t检验表明超弹性NiTi弓丝导致的牙根吸收更多,但差异无统计学意义。

结论

两种弓丝显示出相似 的排齐效率和牙根吸收情况。在排齐阶段,观察到超弹性NiTi弓丝比热激活NiTi弓丝产生更多疼痛。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f918/8423150/1ba64e060a3f/JOS-10-13-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验