Accumulating evidence has shown that vitamin D deficiency has been linked with an up to 300% increase in early implant failure. The aim of this study was to investigate a comprehensive pre-surgical dental support program (DentaMedica) on its ability to increase vitamin D and antioxidant levels prior to implant surgery.
Twenty patients were enrolled in this study. To quantify vitamin D levels, two in-office vitamin D finger-prick tests (10-15 min in length) were compared to levels obtained from a standard laboratory blood test. An antioxidant testing device was also utilised to investigate the impact of this pre-surgical supplementation program on antioxidant scores 0 and 6 weeks post supplementation.
It was first found that 65% of the population had an initial vitamin D deficiency (below 30 ug/ml). After supplementation, vitamin D levels increased from an average of 24.76 ng/ml to 50.11 ng/ml (ranging from 38 to 85.50 ng/ml). No statsitcally significant differences were observed between any of the 3 testing devices (2 in-office finger-prick tests and a standard blood sample). Initial antioxidant levels registered on the biophotonic unit averaged an antioxidant score of 27250 ± 10992.22. Following supplementation, an increase of 54% from baseline values (41950 ± 9276.31) was reported.
The results from this study show convincingly that the majority of the tested population was vitamin D deficient. It was further found that both in-office finger-prick devices demonstrated results comparable to standard lab scores (usually within an average 2-3 ng/ml). Following supplementation, all patients reached sufficient levels following this 4-6 week pre-surgical supplementation program specific to implant dentistry.
越来越多的证据表明,维生素 D 缺乏与早期种植体失败的风险增加高达 300%有关。本研究旨在探讨一种全面的术前牙科支持计划(DentaMedica)在提高维生素 D 和抗氧化剂水平方面的能力,这些水平是在种植术前获得的。
本研究纳入了 20 名患者。为了定量维生素 D 水平,比较了两种办公室内的维生素 D 指尖测试(持续 10-15 分钟)与标准实验室血液测试获得的水平。还使用了一种抗氧化测试设备来研究这种术前补充方案对补充后 0 周和 6 周的抗氧化评分的影响。
首先发现,65%的人群存在初始维生素 D 缺乏症(低于 30 ug/ml)。补充后,维生素 D 水平从平均 24.76ng/ml 增加到 50.11ng/ml(范围为 38-85.50ng/ml)。在任何 3 种测试设备(2 种办公室内的指尖测试和标准血液样本)之间都没有观察到统计学上的显著差异。生物光子单元上最初的抗氧化剂水平平均为 27250±10992.22 的抗氧化评分。补充后,与基线值相比增加了 54%(41950±9276.31)。
本研究结果令人信服地表明,大多数受检人群均存在维生素 D 缺乏症。此外,两种办公室内的指尖测试设备都显示出与标准实验室评分相当的结果(通常在平均 2-3ng/ml 范围内)。补充后,所有患者在特定于种植牙科的 4-6 周术前补充方案后都达到了足够的水平。