Summers Selina, Daniels Natasha Faye, Thahir Azeem, Krkovic Matija
School of Clinical Medicine, University of Cambridge, Addenbrooke's Hospital, Cambridge, CB2 0SP, UK.
Department of Trauma and Orthopaedics, Addenbrookes Major Trauma Unit, Cambridge University Hospitals, Cambridge, UK.
Eur J Orthop Surg Traumatol. 2022 Dec;32(8):1561-1568. doi: 10.1007/s00590-021-03135-5. Epub 2021 Oct 2.
Infected orthopaedic metalwork is challenging to treat. Negative pressure wound therapy (NPWT) with irrigation is an emerging therapy for infected wounds as an adjunct to antibiotic therapy. The senior author had devised a modified technique to augment its efficacy, utilising high-flow rate irrigation and skin closure over the standard NPWT dressing. This novel technique was originally evaluated in a different centre and produced 100% success in metalwork retention. The present study is a reproducibility test of the same technique.
A retrospective review was performed on 24 patients with infected orthopaedic metalwork, including 3 upper limb and 21 lower limb cases, for outcomes relating to implant retention and infection resolution. Patients underwent a modified NPWT technique as an adjunct to antibiotic therapy and surgical debridement. Detailed medical and microbiology information were obtained from the patient records.
23 of 24 (96%) patients had successful metalwork retainment with healed wounds and resolution of infection, allowing fracture union. 27 infective organisms were identified in this cohort, and the antibiotic regimens for each patient are provided. The average follow-up was 663 days. No adverse effects were observed.
This series supports the modified NPWT technique as a safe, reliable and effective adjunct therapy to resolve metalwork infection. The same results have been reproduced as the previous cohort in a different centre.
感染的骨科金属植入物治疗具有挑战性。负压伤口治疗(NPWT)联合冲洗是一种新兴的感染伤口治疗方法,作为抗生素治疗的辅助手段。资深作者设计了一种改良技术以提高其疗效,即在标准NPWT敷料上采用高流速冲洗和皮肤闭合。这项新技术最初在另一个中心进行评估,在金属植入物保留方面成功率达100%。本研究是对同一技术的再现性测试。
对24例感染骨科金属植入物的患者进行回顾性研究,包括3例上肢和21例下肢病例,以评估与植入物保留和感染消退相关的结果。患者接受改良的NPWT技术作为抗生素治疗和手术清创的辅助手段。从患者记录中获取详细的医学和微生物学信息。
24例患者中有23例(96%)成功保留金属植入物,伤口愈合且感染消退,实现骨折愈合。该队列中鉴定出27种感染病原体,并提供了每位患者的抗生素治疗方案。平均随访663天。未观察到不良反应。
本系列研究支持改良的NPWT技术作为解决金属植入物感染的一种安全、可靠且有效的辅助治疗方法。在不同中心再现了与先前队列相同的结果。