Femtosecond laser-assisted cataract surgery versus conventional phacoemulsification: comparison of internal aberrations and visual quality.

机构信息

Eye Center of the Second Affiliated Hospital, School of Medicine, Zhejiang University, No. 88 Jiefang Road, Hangzhou, 310009, Zhejiang Province, China.

出版信息

Graefes Arch Clin Exp Ophthalmol. 2022 Mar;260(3):901-911. doi: 10.1007/s00417-021-05441-4. Epub 2021 Oct 12.

Abstract

PURPOSE

To compare the internal aberrations and optical quality after femtosecond laser-assisted cataract surgery (FLACS) and conventional phacoemulsification cataract surgery (CPCS).

METHODS

This study included patients who received FLACS or CPCS from January 2016 to July 2019. Postoperative examinations included wavefront measurements under pupil diameters of 3.0 mm and 5.0 mm, intraocular lens (IOL) decentration, visual acuity (VA), and refractive outcomes. Visual quality was measured with Strehl ratio and modulation transfer function (MTF). Subgroup analyses were conducted based on monofocal or multifocal-extended depth of focus (EDOF) IOL.

RESULTS

The study consisted of 221 eyes (105 eyes in FLACS and 116 eyes in CPCS). With a pupil diameter of 5.0 mm, FLACS demonstrated a significantly lower root mean square of total internal aberration (P = 0.004), higher order aberrations (HOAs) (P = 0.034), tilt (P = 0.049), coma (P = 0.004), and spherical aberration (P = 0.014). IOL tilt was found to be positively correlated with total internal aberration (P < 0.001), HOAs (P < 0.001), and coma (P < 0.001). The FLACS group presented significantly smaller IOL decentration than the CPCS group (P < 0.001), but there were no significant differences in terms of VA and refractive outcomes between groups. In the multifocal-EDOF subgroup, Strehl ratio and MTF values were significantly higher in the femtosecond group with a 3.0-mm pupil.

CONCLUSION

FLACS induced significantly lower values of IOL tilt, decentration, and internal aberrations compared with the CPCS group with a pupil diameter of 5.0 mm, while no significant differences were found in the VA or optical quality over long-term observation.

TRIAL REGISTRATION

This trial was registered at www.chictr.org.cn (registration number ChiCTR2000038965).

摘要

目的

比较飞秒激光辅助白内障手术(FLACS)和传统超声乳化白内障手术(CPCS)后的眼内像差和光质量。

方法

本研究纳入 2016 年 1 月至 2019 年 7 月接受 FLACS 或 CPCS 的患者。术后检查包括瞳孔直径 3.0mm 和 5.0mm 下的波前测量、人工晶状体(IOL)偏心、视力(VA)和屈光结果。使用斯特列尔比和调制传递函数(MTF)测量视觉质量。根据单焦点或多焦点扩展景深(EDOF)IOL 进行亚组分析。

结果

该研究共纳入 221 只眼(FLACS 组 105 只眼,CPCS 组 116 只眼)。瞳孔直径为 5.0mm 时,FLACS 组总眼内像差的均方根(RMS)明显更低(P=0.004),高阶像差(HOAs)(P=0.034)、倾斜(P=0.049)、彗差(P=0.004)和球差(P=0.014)更高。发现 IOL 倾斜与总眼内像差(P<0.001)、HOAs(P<0.001)和彗差(P<0.001)呈正相关。FLACS 组的 IOL 偏心明显小于 CPCS 组(P<0.001),但两组间 VA 和屈光结果无显著差异。在多焦点-EDOF 亚组中,瞳孔 3.0mm 时,飞秒组的斯特列尔比和 MTF 值明显更高。

结论

与瞳孔 5.0mm 时的 CPCS 组相比,FLACS 诱导的 IOL 倾斜、偏心和眼内像差值显著降低,而长期观察时 VA 或光质量无显著差异。

试验注册

本试验在中国临床试验注册中心(ChiCTR2000038965)注册。