Suppr超能文献

薄瓣准分子原位角膜磨镶术相关干眼:飞秒激光与机械微型角膜刀辅助准分子原位角膜磨镶术的比较研究

Thin-Flap Laser In Situ Keratomileusis-Associated Dry Eye: A Comparative Study Between Femtosecond Laser and Mechanical Microkeratome-Assisted Laser In Situ Keratomileusis.

作者信息

Abdel-Radi Mahmoud, Abdelmotaal Hazem, Anwar Mohamed

机构信息

Department of Ophthalmology, Assiut University, Asyut, Egypt.

出版信息

Eye Contact Lens. 2022 Jan 1;48(1):20-26. doi: 10.1097/ICL.0000000000000850.

Abstract

OBJECTIVE

To assess and compare postlaser in situ keratomileusis (LASIK) dry eye after LASIK with planned thin flaps created by a femtosecond laser (FS) and mechanical microkeratome (MK).

METHODS

Patients were stratified according to the flap creation technique into FS and MK groups with planned 100 μm flap thickness in all eyes. Dry eye parameters including tear film break-up time (TBUT), Schirmer I test, ocular surface disease index (OSDI), and lower tear meniscus height and area (tear meniscus height [TMH] and tear meniscus area [TMA]) were assessed before surgery and at 3 and 6 months after surgery.

RESULTS

The study included 102 eyes of 55 patients (52 eyes underwent FS-LASIK/50 eyes underwent MK-LASIK). The preoperative characteristics including age, gender, and spherical equivalents were similar in both groups (P>0.05). The difference in postoperative flap thickness was statistically significant (P<0.05). In each group, dry eye parameters showed a statistically significant worsening (P value<0.001) at 3 months with later significant improvement at 6 months but did not return to baseline. The mean TBUT, Schirmer I, and lower TMH and TMA were statistically higher, and the mean OSDI was statistically lower in FS-LASIK than the MK-LASIK group at both 3 and 6 months (P value<0.001). The depth of ablation had a statistically significant correlation with Schirmer I at 6 months and OSDI at both 3 and 6 months post-LASIK (P<0.05).

CONCLUSION

The use of femtosecond laser technology in performing thin-Flap LASIK eye surgeries has improved the outcome of post-LASIK dry eye when compared with the mechanical microkeratome.

摘要

目的

评估并比较飞秒激光(FS)和机械微型角膜刀(MK)制作预定薄瓣的准分子原位角膜磨镶术(LASIK)术后的干眼情况。

方法

根据瓣制作技术将患者分为FS组和MK组,所有眼睛预定瓣厚度均为100μm。在手术前以及手术后3个月和6个月评估干眼参数,包括泪膜破裂时间(TBUT)、泪液分泌试验I、眼表疾病指数(OSDI)以及下方泪河高度和面积(泪河高度[TMH]和泪河面积[TMA])。

结果

该研究纳入了55例患者的102只眼(52只眼接受FS-LASIK/50只眼接受MK-LASIK)。两组术前特征包括年龄、性别和等效球镜度数相似(P>0.05)。术后瓣厚度差异具有统计学意义(P<0.05)。每组中,干眼参数在术后3个月均有统计学意义的恶化(P值<0.001),随后在6个月有显著改善,但未恢复至基线水平。在术后3个月和6个月时,FS-LASIK组的平均TBUT、泪液分泌试验I以及下方TMH和TMA均显著高于MK-LASIK组,而平均OSDI则显著低于MK-LASIK组(P值<0.001)。LASIK术后6个月时,消融深度与泪液分泌试验I以及术后3个月和6个月时的OSDI均有显著相关性(P<0.05)。

结论

与机械微型角膜刀相比,飞秒激光技术用于进行薄瓣LASIK眼科手术可改善LASIK术后干眼的情况。

相似文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验