Dermatology Department, Hospital Universitario Virgen del Rocío, Sevilla, Spain.
Dermatology Service, Department of Medicine, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
J Invest Dermatol. 2022 May;142(5):1291-1299.e2. doi: 10.1016/j.jid.2021.09.029. Epub 2021 Oct 23.
Ex vivo confocal microscopy (EVCM) generates digitally colored purple-pink images similar to H&E without time-consuming tissue processing. It can be used during Mohs surgery for rapid detection of basal cell carcinoma (BCC); however, reading EVCM images requires specialized training. An automated approach using a deep learning algorithm for BCC detection in EVCM images can aid in diagnosis. A total of 40 BCCs and 28 negative (not-BCC) samples were collected at Memorial Sloan Kettering Cancer Center to create three training datasets: (i) EVCM image dataset (663 images), (ii) H&E image dataset (516 images), and (iii) a combination of the two datasets. A total of seven BCCs and four negative samples were collected to create an EVCM test dataset (107 images). The model trained with the EVCM dataset achieved 92% diagnostic accuracy, similar to the H&E model (93%). The area under the receiver operator characteristic curve was 0.94, 0.95, and 0.94 for EVCM-, H&E-, and combination-trained models, respectively. We developed an algorithm for automatic BCC detection in EVCM images (comparable accuracy to dermatologists). This approach could be used to assist with BCC detection during Mohs surgery. Furthermore, we found that a model trained with only H&E images (which are more available than EVCM images) can accurately detect BCC in EVCM images.
离体共聚焦显微镜 (EVCM) 生成类似于 H&E 的数字化彩色紫粉色图像,无需耗时的组织处理。它可用于 Mohs 手术中快速检测基底细胞癌 (BCC);然而,阅读 EVCM 图像需要专门的培训。一种使用深度学习算法自动检测 EVCM 图像中 BCC 的方法可以辅助诊断。总共在纪念斯隆凯特琳癌症中心收集了 40 个 BCC 和 28 个阴性(非-BCC)样本,创建了三个训练数据集:(i) EVCM 图像数据集(663 张图像),(ii) H&E 图像数据集(516 张图像),和 (iii) 两个数据集的组合。总共收集了 7 个 BCC 和 4 个阴性样本,创建了一个 EVCM 测试数据集(107 张图像)。使用 EVCM 数据集训练的模型达到了 92%的诊断准确率,与 H&E 模型(93%)相似。EVCM-、H&E-和组合训练模型的受试者工作特征曲线下面积分别为 0.94、0.95 和 0.94。我们开发了一种用于 EVCM 图像中自动 BCC 检测的算法(与皮肤科医生的准确率相当)。这种方法可用于辅助 Mohs 手术中的 BCC 检测。此外,我们发现仅使用 H&E 图像(比 EVCM 图像更易获得)训练的模型可以准确检测 EVCM 图像中的 BCC。