Suppr超能文献

瑞典交互式阈值算法快速版与瑞典交互式阈值算法标准版在青光眼患者中的比较研究

A Comparative Study between Swedish Interactive Thresholding Algorithm Faster and Swedish Interactive Thresholding Algorithm Standard in Glaucoma Patients.

作者信息

Mendieta Núria, Suárez Joel, Blasco Cristina, Muñiz Romina, Pueyo Carmen

机构信息

Department of Ophthalmology, Esperanza Hospital, Barcelona, Spain.

Department of Ophthalmology, Creu Groga Ophthalmologic Institute, Calella, Spain.

出版信息

J Curr Ophthalmol. 2021 Oct 22;33(3):247-252. doi: 10.4103/joco.joco_148_20. eCollection 2021 Jul-Sep.

Abstract

PURPOSE

To compare the results of the new strategy Swedish Interactive Thresholding Algorithm (SITA) Faster to the results of SITA Standard in patients with glaucoma.

METHODS

This was a cross-sectional study of 49 patients with glaucoma and previous experience with standard automated perimetry. Two consecutive tests were performed in random order, one with SITA Standard and another one with SITA Faster, in the studied eye of each patient. Comparisons were made for test time, mean deviation (MD), visual field index (VFI), and number of depressed points in pattern deviation map and total deviation map for every level of significance.

RESULTS

The average test time was 56% shorter with SITA Faster ( < 0.001). The intraclass correlation coefficient (ICC) for MD and VFI showed excellent agreement between both strategies, ICC = 0.98 (95% confidence interval [CI]: 0.96, 0.99) and ICC = 0.97 (95% CI: 0.95, 0.99), respectively. For the number of depressed points in total deviation map and pattern deviation map, ICC demonstrated good agreement with values between 0.8 and 0.95.

CONCLUSIONS

Our study shows that SITA Faster is a shorter test with strong agreement with SITA Standard parameters. These results suggest that SITA Faster could replace SITA Standard for glaucoma diagnosis.

摘要

目的

比较青光眼患者中新型瑞典交互式阈值算法(SITA)Faster与SITA Standard的检测结果。

方法

这是一项对49例青光眼患者且有标准自动视野计检测经验的横断面研究。在每位患者的患眼中,以随机顺序进行连续两次检测,一次采用SITA Standard,另一次采用SITA Faster。对每个显著性水平下的检测时间、平均偏差(MD)、视野指数(VFI)以及模式偏差图和总偏差图中压低点数进行比较。

结果

SITA Faster的平均检测时间缩短了56%(<0.001)。MD和VFI的组内相关系数(ICC)显示两种检测策略之间具有高度一致性,分别为ICC = 0.98(95%置信区间[CI]:0.96,0.99)和ICC = 0.97(95%CI:0.95,0.99)。对于总偏差图和模式偏差图中的压低点数,ICC显示出良好的一致性,值在0.8至0.95之间。

结论

我们的研究表明,SITA Faster检测时间更短,且与SITA Standard参数高度一致。这些结果表明,SITA Faster可替代SITA Standard用于青光眼诊断。