Department of Electro-Optical Engineering, Southern Taiwan University of Science and Technology, Tainan 71005, Taiwan.
Sensors (Basel). 2021 Nov 8;21(21):7410. doi: 10.3390/s21217410.
A low-cost polyethylene terephthalate fluidic sensor (PET-FS) is demonstrated for the concentration variation measurement on fluidic solutions. The PET-FS consisted of a triangular fluidic container attached with a birefringent PET thin layer. The PET-FS was injected with the test liquid solution that was placed in a common path polarization interferometer by utilizing a heterodyne scheme. The measured phase variation of probe light was used to obtain the information regarding the concentration change in the fluidic liquids. The sensor was experimentally tested using different concentrations of sodium chloride solution showing a sensitivity of 3.52 ×10 deg./refractive index unit (RIU) and a detection resolution of 6.25 × 10 RIU. The estimated sensitivity and detection resolutions were 5.62 × 10 (deg./RIU) and 6.94 × 10 RIU, respectively, for the hydrochloric acid. The relationship between the measured phase and the concentration is linear with an R-squared value reaching above 0.995.
一种低成本的聚对苯二甲酸乙二醇酯流体制动传感器 (PET-FS) 被证明可用于测量流体制动液的浓度变化。PET-FS 由一个附加有双折射 PET 薄膜的三角形流体制动容器组成。PET-FS 通过利用外差方案注入测试液体溶液,该测试液体溶液被放置在一个公共路径偏振干涉仪中。测量的探测光的相位变化用于获得关于流体制动液中浓度变化的信息。该传感器使用不同浓度的氯化钠溶液进行了实验测试,显示出 3.52×10 度/折射率单位 (RIU) 的灵敏度和 6.25×10 RIU 的检测分辨率。对于盐酸,估计的灵敏度和检测分辨率分别为 5.62×10(度/RIU)和 6.94×10 RIU。测量相位与浓度之间的关系是线性的,R 平方值超过 0.995。