Suppr超能文献

便携式电动按摩器在不同频率下肌筋膜松解的急性效应:一项随机初步研究。

Acute effects of myofascial release with portable electric massager at different frequencies: A randomized pilot study.

机构信息

Human Performance Laboratory, Universidade Federal do Amazonas, Faculdade de Educação Física e Fisioterapia, Manaus, AM, Brazil; Programa de Pós Graduação Stricto Sensu em Ciências da Saúde, Faculdade de Medicina, Universidade Federal do Amazonas, Faculdade de Educação Física e Fisioterapia, Manaus, AM, Brazil; Programa de Pós Graduação Stricto Sensu em Ciências do Movimento Humano, Faculdade de Educação Física e Fisioterapia, Universidade Federal do Amazonas, Faculdade de Educação Física e Fisioterapia, Manaus, AM, Brazil.

Biomechanics Laboratory, Federal University of Santa Catarina, Florianópolis, SC, Brazil.

出版信息

J Bodyw Mov Ther. 2021 Oct;28:225-230. doi: 10.1016/j.jbmt.2021.07.037. Epub 2021 Aug 8.

Abstract

INTRODUCTION

The present study aimed to analyze the acute effects of a myofascial release session (MFR) with a portable electric massager (PEM) at different frequencies (25 Hz and 52 Hz) on the superficial and deep fascial motion.

METHODS

The limbs of fourteen participants (12 men and 2 women, age = 34 ± 10 years; height = 1.74 ± 0.09 m; weight = 72.77 ± 13.1 kg; right thigh fat thickness = 4.18 ± 3.49 mm; left thigh fat thickness = 4.13 ± 3.35 mm) were randomized to one of the two PEM frequencies (25 Hz vs. 52 Hz). All evaluations were carried out at the same time of day and by the same evaluator (blind). The protocol consisted of 9 min of MFR on the vastus lateralis, alternating between three sites of 5 cm. Before and after the MFR session, the fascial motion was measured in the vastus lateralis (superficial and deep layer) using B-mode ultrasound at two knee positions (0° and 45°).

RESULTS

The superficial and deep layers presented significant increases in fascia length after myofascial release with the knee extended 0° (p < 0.001) and flexed 45° (p < 0.001). In addition, the fascial motion was not influenced by the frequency applied during the experimental protocol and was independent of layer and knee position. However, the deep layer showed an increase at knee flexed at 45° compared to the superficial layer. On the other hand, there was no difference between layers when the knee was extended (0°). The findings of this study indicate that PEM appears to be effective in changing the fascial motion of the vastus lateralis.

摘要

简介

本研究旨在分析使用便携式电动按摩器(PEM)以不同频率(25Hz 和 52Hz)进行一次肌筋膜松解治疗对浅层和深层筋膜运动的急性影响。

方法

14 名参与者(12 名男性和 2 名女性,年龄=34±10 岁;身高=1.74±0.09m;体重=72.77±13.1kg;右大腿脂肪厚度=4.18±3.49mm;左大腿脂肪厚度=4.13±3.35mm)的四肢被随机分配到两种 PEM 频率之一(25Hz 与 52Hz)。所有评估均在同一天和同一评估员(盲法)进行。方案包括在股外侧肌上进行 9 分钟的肌筋膜松解,在三个 5cm 的部位之间交替进行。在肌筋膜松解治疗前后,使用 B 型超声在两个膝关节位置(0°和 45°)测量股外侧肌的筋膜运动(浅层和深层)。

结果

膝关节伸展 0°(p<0.001)和弯曲 45°(p<0.001)时,浅层和深层筋膜长度在肌筋膜松解后均显著增加。此外,筋膜运动不受实验方案中应用频率的影响,并且与层和膝关节位置无关。然而,与浅层相比,深层在膝关节弯曲 45°时表现出增加。另一方面,当膝关节伸展(0°)时,各层之间没有差异。本研究的结果表明,PEM 似乎可以有效改变股外侧肌的筋膜运动。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验